Concordance Study on Molecular Detection of Thyroid Nodules by Ultrasound Guided Fine Needle Aspiration.
Su Meng, Jianxiong Sun, Changliang Zhang, Zhixue Yang, Jinrong Wei, Si Chen, Yanan Li, Xiaoxiao Dai,
Department of Thyroid and Breast, The Second Affiliated Hospital of Soochow University, Suzhou, China. · Advanced Molecular Pathology Institute of Soochow University and SANO, Suzhou, China.
Key points
From the paper's conclusion- Inter-specimen concordance is driven mainly by tumor heterogeneity; lesion diameter is unlikely to be a major determinant. Tumor cell proportion, though unquantified, remains a plausible contributor. Surgical tissue yields richer profiles but is not a perfect reference. Standardized FNA sampling and separate puncture of each suspicious nodule may improve concordance.
Abstract
BACKGROUND: Fine needle aspiration (FNA) constitutes the primary preoperative evaluation for thyroid nodules. Targeted Next-generation sequencing (NGS) of FNA samples increasingly informs clinical assessment. Molecular concordance between FNA and surgical tissues may be modulated by lesion diameter and heterogeneity. METHODS: Among 91 prospectively enrolled patients with suspected thyroid nodules, FNA-fresh surgical tissue matching yielded 76 patients per cohort: 85 matched pairs for DNA NGS, 82 pairs from 72 patients for RNA NGS after four pairs failed library construction. Concordance was assessed by Cohen's kappa, positive (PPA) and negative (NPA) percent agreement; generalized estimating equations and patient-level cluster bootstrap addressed within-patient clustering. RESULTS: DNA NGS concordance was 88.24% (κ = 0.60, cluster-adjusted 95% CI: 0.37-0.79; PPA 89.04%, NPA 83.33%); RNA NGS concordance was 98.78% (κ = 0.88, 95% CI: 0.54-1.00). DNA yield was higher in surgical tissue than FNA (p < 0.0001); library yield did not differ (p = 0.376). Lesion diameter was comparable between concordant and discordant pairs (p = 0.840; minimum detectable effect d ≈0.95). Concordance did not differ between solitary- and multiple-nodule specimens (p = 0.418) or between malignant and benign lesions on both platforms, although patient-level discordance was numerically higher in multinodular disease (37.5% vs. 10.3%). CONCLUSION: Inter-specimen concordance is driven mainly by tumor heterogeneity; lesion diameter is unlikely to be a major determinant. Tumor cell proportion, though unquantified, remains a plausible contributor. Surgical tissue yields richer profiles but is not a perfect reference. Standardized FNA sampling and separate puncture of each suspicious nodule may improve concordance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Application of fine-needle aspiration biopsy combined with multi-gene testing in the differential diagnosis of benign and malignant C-TIRADS 4 thyroid nodules.Frontiers in medicine · 2026
- Molecular profiling of thyroid nodules on cytologic samples: Findings from an Italian multi‐institutional cohortCancer Cytopathology · 2025
- Diagnostic performance of next-generation sequencing in thyroid nodules and molecular correlates of tumor aggressiveness in papillary thyroid carcinoma.Frontiers in endocrinology · 2026
- Design and analytical validation of Nexthyro 2.0, a custom next-generation sequencing panel integrating DNA mutation profiling and RNA fusion detection for routine thyroid pathology specimensArchiv für Pathologische Anatomie und Physiologie und für Klinische Medicin · 2026
- Molecular Testing in Indeterminate Thyroid Nodules: Current Evidence, Clinical Utility, and Practical Considerations.Rejuvenation research · 2026
- A Key Biomarker lnc-ABCA12-5:2 Compensating Diagnostic Deficiencies for Indeterminate Thyroid Nodules and Genetically Wild-Type Thyroid Malignancies.Oncology research · 2026