A Simple Percutaneous Fiducial Marker Placement Technique Using a 22‐Gauge Needle and Platinum Embolization Coils for Real‐Time Tumor‐Tracking Radiotherapy
Masayoshi Inoue, Emiko Shimoda, Youhei Kanamori, Yuki Suenaga, Mei Nikimoto, Yuya Wakita, Natsuhiko Saito, Hidehiko Taguchi,
Key points
From the paper's conclusion- Herein, we evaluated the technical feasibility and procedure‐related outcomes of a simple percutaneous fiducial marker placement technique using platinum embolization coils delivered through a 22‐gauge needle.
Abstract
Real‐time tumor‐tracking radiotherapy (RTRT) requires reliable visualization of fiducial markers to ensure accurate dose delivery to moving targets. Fiducial markers containing large amounts of metals may facilitate greater radiographic detectability; however, they may require larger‐caliber delivery needles or introducer systems, potentially increasing procedural invasiveness. Herein, we evaluated the technical feasibility and procedure‐related outcomes of a simple percutaneous fiducial marker placement technique using platinum embolization coils delivered through a 22‐gauge needle. Platinum embolization coils were percutaneously implanted as fiducial markers using a 22‐gauge needle in 15 patients who underwent RTRT using SyncTraX. We retrospectively assessed technical success, procedure‐related complications, and marker tracking availability during treatment. Fiducial marker placement was technically successful in all patients (100%). The median procedure time was 25 min (range, 10–35 min). Grade 1 pneumothorax occurred in one patient (6.7%). No severe procedure‐related adverse events were observed. The median tracking efficiency, which reflects marker tracking availability, was 0.68 (range, 0.58–0.84). Percutaneous placement of platinum embolization coils through a 22‐gauge needle was technically feasible in this limited series, without any severe procedure‐related adverse events. The technique enables adjustment of localized metal volume by coil length and, when necessary, coil number using a standard delivery needle. Further studies are needed to evaluate site‐specific safety, marker visibility, and intrinsic marker recognition performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real‐time intrafraction 3D spine tracking using gantry‐mounted kV imaging for single fraction high dose functional radiosurgeryMedical Physics · 2026
- Robots for CT-guided needle insertion: clinical implementation and future perspectives.Japanese journal of radiology · 2026
- A Guidewire Trajectory Generation Tool for Interventional MRI SimulationsarXiv · 2026
- Neural pathway-guided radiosurgery: A systematic review and meta-analysis of diffusion tensor imaging applications in stereotactic radiosurgery.Neurosurgical review · 2026
- Marker-Less Lung Tumor Tracking from Real-Time Color X-Ray Fluoroscopic Images Using Cross-Patient Deep Learning ModelBioengineering · 2025
- SURG-27 Fixed gantry versus mobile cone‑beam CT in guiding Robot‑assisted stereotaxis: a neuro-oncologic experience of 66 patientNeuro-Oncology · 2026