Diagnostic Utility of Fasting Blood Glucose and Glycated Hemoglobin Compared to Oral Glucose Tolerance Test for Diabetes Mellitus: A Cross-Sectional Study.
Emmanuel Okrah, Dawudu Abdullah, Beatrice Manu, James Kojo Prah, Samuel Amoah, Benjamin Nyane, Gloria N Nartey, Eugenia N A Ayetey,
Department of Medical Laboratory Science University of Cape Coast Cape Coast Ghana.
Key points
From the paper's conclusion- These findings support the continued use of OGTT as the reference method for diagnosing diabetes mellitus in high‐risk individuals, particularly where early detection is critical.
Abstract
INTRODUCTION: Fasting blood glucose (FBG), glycated hemoglobin (HbA1c), and the oral glucose tolerance test (OGTT) may classify individuals differently when used to assess diabetes mellitus. This exploratory study compared diabetes classification by these methods and evaluated the agreement and diagnostic performance of HbA1c and FBG relative to the study's 2-h post-glucose-load criterion among adults at increased risk of diabetes attending the University of Cape Coast Hospital, Ghana. METHOD: A hospital-based cross-sectional study was conducted among 50 adults with one or more diabetes mellitus risk factors attending the University of Cape Coast Hospital, Ghana. Participants underwent FBG, HbA1c, and a 75-g OGTT on the same day. Diabetes mellitus was defined as FBG ≥ 7.0 mmol/L, 2-h post-glucose-load glucose ≥ 11.1 mmol/L, or HbA1c ≥ 6.5%, according to international diagnostic criteria. Diagnostic agreement between HbA1c and the 2-h post-glucose-load classification was assessed using Cohen's kappa statistic, while sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of HbA1c and FBG were calculated using the 2-h post-glucose-load classification as the reference standard. RESULTS: Among 50 participants, seven (14.0%) met the study's 2-h post-glucose-load criterion for diabetes mellitus, two (4.0%) met the HbA1c criterion, and none met the FBG criterion. Agreement between HbA1c and the post-load classification was 86.0% (Cohen's κ = 0.17). Relative to the post-load criterion, HbA1c sensitivity was 14.3% (95% CI: 0.4%-57.9%) and specificity was 97.7% (95% CI: 87.7%-99.9%). FBG sensitivity was 0.0% (95% CI: 0.0%-41.0%), and specificity was 100.0% (95% CI: 91.8%-100.0%). CONCLUSION: The 2-h post-glucose-load criterion identified more participants with diabetes-range results than HbA1c or FBG in this sample. Although HbA1c demonstrated excellent specificity, its low sensitivity suggests that it may miss a considerable proportion of diabetes cases when used as a standalone diagnostic test. These findings support the continued use of OGTT as the reference method for diagnosing diabetes mellitus in high-risk individuals, particularly where early detection is critical. However, larger, well-powered multicentre studies are needed to validate these results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Discordance Between Fasting Plasma Glucose- and HbA1c-Based Glycemic Classifications and Associated Metabolic and Hemodynamic Profiles in Thai Older Adults.Life (Basel, Switzerland) · 2026
- Superiority of 1 h plasma glucose vs fasting plasma glucose, 2 h plasma glucose and HbA1c for the diagnosis of type 2 diabetesDiabetologia · 2025
- Beyond Global Cut-offs: The Predictive Value of Glycated Haemoglobin for Dysglycaemia in South Asia.Indian journal of endocrinology and metabolism · 2026
- Fasting Plasma Glucose Outperforms Glycated Hemoglobin in Identifying Metabolic Syndrome: Evidence from a Population-based Cross-sectional Study in Rural Bangladesh2026
- Who Should Have an HbA1c? Development and External Validation of a Dysglycaemia Prediction Model Using Only Routinely Available Data.Healthcare (Basel, Switzerland) · 2026
- An improved approach to modelling patient reclassification: HbA 1c as an exampleClinical Chemistry and Laboratory Medicine (CCLM) · 2026