Real‐Time HIL Validation of a Model‐Free Online PSO‐Adaptive PI Controller for Battery–Supercapacitor DC‐Bus Voltage Regulation
Mohamed Fadi Kethiri, Faiza Zaamoune, Mehmet Yavuz, Omar Charrouf
Key points
From the paper's conclusion- Experimental results under a 24 s load‐current profile show that the proposed PSO‐adaptive PI controller reduces the RMSE from 1.38 V to 0.83 V, the maximum voltage error from 11.39 V to 4.71 V, and the maximum voltage deviation from 9.49% to 3.93% compared with a Lyapunov‐guided fixed‐gain PI reference.
Abstract
Battery–supercapacitor hybrid energy storage systems are widely used to improve DC‐bus stability under fast load‐current variations. In such systems, the battery supplies the low‐frequency energy demand, while the supercapacitor compensates rapid transient components. However, fixed‐gain PI voltage controllers may lose performance when the operating point, storage states, converter conditions, or load‐current demand vary during operation. This paper proposes a model‐free online particle swarm optimization (PSO) tuner for adaptive PI regulation of the DC‐bus voltage in a battery–supercapacitor hybrid storage system. The proposed method does not require an analytical model of the battery, supercapacitor, bidirectional converters, DC‐link capacitance, or load. Each particle represents a candidate pair of proportional and integral gains, and its quality is evaluated from the measured DC‐bus voltage error and internally computed PI quantities over a short time window. The fitness function combines the squared tracking error, error variation, error‐worsening penalty, weak control‐effort penalty, and saturation penalty. To improve real‐time safety, each tested particle is blended with the current global‐best gain vector before being applied to the controller, while a stabilizing PI gain pair is preserved as an elitist fallback particle. The proposed controller is integrated with a frequency‐separation energy management system and validated through real‐time hardware‐in‐the‐loop implementation using separated control‐side and plant‐side execution. Experimental results under a 24 s load‐current profile show that the proposed PSO‐adaptive PI controller reduces the RMSE from 1.38 V to 0.83 V, the maximum voltage error from 11.39 V to 4.71 V, and the maximum voltage deviation from 9.49% to 3.93% compared with a Lyapunov‐guided fixed‐gain PI reference. For the examined load profile, the results support the practical feasibility of measured‐error‐based online PI tuning in the tested hardware‐in‐the‐loop configuration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bio-Inspired PSO Optimization of Fuzzy Membership Boundaries and PI Gains for a 48 V Synchronous Boost Converter.Biomimetics (Basel, Switzerland) · 2026
- Energy management of hybrid storage in an electric bus via optimized dual-level controlJournal of Energy Storage · 2026
- Particle Swarm Optimisation-Based Receding-Horizon Energy Management for a PV–Battery Household with Electric Vehicle and Heat Pump IntegrationElectronics · 2026
- Hybrid Supercapacitor–Battery System for PV Modules Under Partial Shading: Modeling, Simulation, and ImplementationEnergies · 2025
- Enhanced power management in PV-Integrated hybrid energy storage systems using fuzzy 2DOF-PI control optimized by hippopotamus algorithmScientific Reports · 2026
- Optimal Energy Storage Management in Grid-Connected PV-Battery Systems Based on GWO-PSOEnergies · 2025