Break‐Even Conditions for HTS‐HVDC in Constrained High‐Capacity Renewable‐Energy Transmission Corridors
Alireza Ganjovi, Saman A. Gorji
Key points
From the paper's conclusion- Constrained transmission corridors motivate comparison of high‐temperature superconducting high‐voltage direct‐current (HTS‐HVDC) with conventional VSC‐HVDC under a common receiving‐end service and contingency requirement.
Abstract
Constrained transmission corridors motivate comparison of high‐temperature superconducting high‐voltage direct‐current (HTS‐HVDC) with conventional VSC‐HVDC under a common receiving‐end service and contingency requirement. This study links three questions: how transmission ratings determine installed reserve, how much additional conventional corridor capital is required for parity and what conductor procurement price permits parity. The calculation purchases complete cable, converter and cooling inventories for independent modules and evaluates lifecycle expenditure and delivered energy. A 2‐GW conventional reference is compared with 2‐, 3‐, 4‐ and 5‐GW HTS planning modules using a common converter–cost relationship. At 2.1 GW receiving‐end power and 500 km, the additional conventional capital required for parity is approximately USD 0.80 billion for equal‐2‐GW modules and USD 1.39 billion for 5‐GW HTS modules. Fewer HTS assemblies can therefore coincide with a higher cost of installed reserve. Conductor‐price thresholds depend on that architecture and the assumed additional‐corridor capital; three heat‐ingress scenarios show their thermal sensitivity. Reliability and input uncertainty qualify these conditions rather than establish commercial feasibility. The calculations use published component correlations and explicit author cost and reliability scenarios. Historical project comparisons do not validate the conventional coefficients, and conductor‐current evidence does not qualify a complete 5‐GW cable system. The outputs are architecture‐specific conditions for further engineering and project appraisal, not estimates of demonstrated avoided corridor expenditure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Review of the Developments in Capacity-Uprating Conductors for Overhead Transmission LinesCoatings · 2025
- HVDC Systems and renewable energy in a comparative study of technologies and applicationse-Prime – Nexus of Electrical Electronic and Intelligent Engineering · 2026
- Type Tests of a 10 kV/1 MVar High-Temperature Superconducting Air-Core Shunt ReactorIEEE Transactions on Applied Superconductivity · 2026
- Frequency-Support Capability Verification of Multiple VSC-HVDC Links Through Power–Energy–Duration Envelopes and Shared-Resource De-DuplicationElectronics · 2026
- Research on a Short-Circuit Current Suppression Strategy for Multi-DC Receiving-End Power Grids Integrating Fuzzy Comprehensive Evaluation and Coordinated Optimization of Grid Structure and Current-Limiting DevicesEnergies · 2026
- Coordinated Fault Ride-Through Control for a Hierarchically Connected VSC-HVDC SystemEnergies · 2026