Full‐Scale Experimental Evaluation of the In‐Plane Seismic Interaction Between Drywall Partitions and Two‐Story Reinforced Concrete Building: Mitigating Structural Vulnerabilities Through Polymer‐Based Isolation
Jorge I. Garcés, Francisco J. Pallarés, Luis Pallarés
Key points
From the paper's conclusion- Finally, the isolated configuration exhibited a stable equivalent viscous damping ratio between 5% and 6%, aligning the structural response more closely with code design assumptions for non‐interacting infills.
Abstract
Although drywall partitions are generally regarded as non‐structural elements, they interact with the primary structural frame and can significantly influence the structural response during seismic events. This study presents a full‐scale experimental investigation to quantify this seismic interaction and validate a novel polymer‐based isolation strategy, denoted as SISPYL. Two identical full‐scale, two‐story reinforced concrete buildings were subjected to quasi‐static cyclic loading. One building featured standard rigid drywall partitions, while the other incorporated the isolation system, replacing specific sections of the rigid gypsum core with a deformable polyurethane polymer at both perimeter and connection interfaces. The standard rigid installation exhibited an initial lateral stiffness of 20.93 kN/mm. This rigid composite action triggered a dominant membrane behaviour, transferring severe localised shear forces to the structural connections. This induced a premature soft‐story mechanism at the ground level, culminating in widespread structural and non‐structural failure before a roof drift ratio of 1.62%. Conversely, the deformation decoupling achieved by the SISPYL system reduced the initial lateral stiffness by 32.4% (to 14.15 kN/mm) compared to the standard configuration. This isolation prevented the transfer of damaging membrane forces, mitigated shear damage in the reinforced concrete joints, and restored a uniform story drift distribution. Consequently, the isolated frame accommodated lateral deformations up to a roof drift ratio of 2.39% while developing its intended distributed flexural yielding. Finally, the isolated configuration exhibited a stable equivalent viscous damping ratio between 5% and 6%, aligning the structural response more closely with code design assumptions for non‐interacting infills.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental Dataset From Full‐Scale Test Results on Nonplanar Beam–Slab to Shear Wall Connections Under Cyclic Loading (ERIES‐NOBLE Project)Earthquake Spectra · 2026
- Vertical seismic isolation systems for new and existing structures in process and nuclear power plantsEngineering Structures · 2026
- Simplified Macro-Model for Non-Interactive Masonry Infill WallsJournal of Earthquake Engineering · 2026
- Seismic Behavior Research of IFW Assembled Shear WallThe Structural Design of Tall and Special Buildings · 2026
- Influence of Partial and Asymmetric Strengthening of Timber Floors on the Seismic and Gravity-Load Response of Historic Unreinforced Masonry BuildingsBuildings · 2026
- Design Abaci for Shaking-Table Testing of Hybrid Steel-Timber Frames with Flexible Polyurethane Interlayers.Materials (Basel, Switzerland) · 2026