Determination of Posaconazole in Serum From Patients Undergoing Treatment for Hematological Malignancies by High‐Performance Liquid Chromatography With Electrochemical Detection
Akira Kotani, Keishiro Kuniyoshi, Masaaki Ito, Yusuke Yagi, Kohei Jobu, Yukihiro Hamada, Koichi Machida, Hideki Hakamata
Key points
From the paper's conclusion- In conclusion, the proposed HPLC‐ECD method provides sensitive, accurate, and precise quantification of PSCZ in human serum and is suitable for clinical application.
Abstract
A high‐performance liquid chromatography system coupled with electrochemical detection (HPLC‐ECD) was developed for the determination of posaconazole (PSCZ). Chromatographic separation was achieved on an octadecylsilyl (ODS) column with an internal diameter of 1.0 mm using a mobile phase consisting of water–acetonitrile–formic acid (60:40:0.5, v/v/v) delivered at 50 μL/min. The applied potential for PSCZ detection was set at +0.65 V versus Ag/AgCl based on hydrodynamic voltammetry. Under these conditions, PSCZ was eluted at 6.8 min. Peak height showed a linear response over the concentration range of 2.0 μg/L to 1.0 mg/L ( r = 0.999). The limit of detection was 0.67 μg/L (signal‐to‐noise ratio, S/N = 3). The HPLC‐ECD method was applied to the determination of PSCZ concentrations in serum of three patients undergoing treatment for hematological malignancies and receiving PSCZ delayed‐release tablets at a maintenance dose of 300 mg/day. In the quantitative analysis, the repeatability was within a relative standard deviation (RSD) of 2.4% ( n = 5), and their recoveries exceeded 95.7% with an RSD below 2.5% ( n = 5). In conclusion, the proposed HPLC‐ECD method provides sensitive, accurate, and precise quantification of PSCZ in human serum and is suitable for clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Green and lean: A validated RP-HPLC-VWD method for simultaneous determination of hydroquinone, methylparaben, fluocinolone acetonide, and propylparaben.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- In vitro feasibility studies for clinical microdialysis with lipophilic compounds: A case study with the antifungal posaconazole.Journal of pharmaceutical sciences · 2026
- Development and Validation of an Ultra‐Fast UPLC–MS/MS Method for Simultaneous Quantification of Lodenafil and Lodenafil Carbonate in Human Liver Microsomes: Depletion Rate and Metabolic Stability AssessmentBiomedical Chromatography · 2026
- A robust liquid chromatography–tandem mass spectrometry method for accurate quantification of omeprazole in human plasma: Integration of International Council for Harmonisation guidelines for pharmacokinetic applicationActa Chromatographica · 2026
- AQbD-Driven RP-HPLC Method for Rapid Dissolution Monitoring of Amiodarone Hydrochloride Tablets Without Sample Dilution.Pharmaceuticals (Basel, Switzerland) · 2026
- Development and clinical validation of HPLC method for precise quantification of paclitaxel in plasma from breast cancer patients.PloS one · 2026