Development of an Electronic Tongue for the Analysis of Particulate Matter Samples Collected in the City of Rio de Janeiro
Camilla Machado Gentil Ribeiro, Cleyton Martins da Silva, Graciela Arbilla, Maiara Oliveira Salles
Key points
From the paper's conclusion- This study presents a voltammetric electronic tongue for the discrimination of fine particulate matter (PM 2.5) collected at three distinct urban locations in Rio de Janeiro, Brazil.
Abstract
This study presents a voltammetric electronic tongue for the discrimination of fine particulate matter (PM 2.5) collected at three distinct urban locations in Rio de Janeiro, Brazil. A Screen‐Printed Electrode (SPE) was developed using a low‐cost handmade ink (optimized at 20% w/w glass varnish, 40% w/w graphite, and 40% w/w solvent, with PET bottles used as the substrate). The electrode was characterized by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), scanning electron microscopy (SEM), and Raman spectroscopy. Following acid digestion, PM samples collected from the Rio de Janeiro Botanical Garden (RJBG), the Rebouças Tunnel (RT), and the Institute of Chemistry at UFRJ were analyzed by square wave voltammetry (SWV). Exploratory analysis using principal component analysis (PCA) and hierarchical cluster analysis (HCA) demonstrated that raw voltammetric data provided significantly superior sample separation compared to normalized data. Temporal evaluation revealed that seasonal factors and dry weather conditions influenced the grouping behavior, causing partial overlap between RJBG and RT samples. Finally, an artificial neural network (ANN) classification model constructed using raw data achieved a classification accuracy of 75% in the independent test set, classifying samples according to their sampling‐site labels, although temporal and seasonal factors may also have contributed to the observed differences.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An electrocatalytic, cobalt-phthalocyanine screen-printed carbon voltammetric sensor for the measurement of the antioxidant gallic acid in instant coffeeJournal of Food Science and Technology · 2026
- Development and Preliminary Analytical Evaluation of a Portable Electronic-Nose Method for Discriminating Cassia grandis-Enriched Rice Beverages Using Chemometrics and HS-SPME-GC-MSChemosensors · 2026
- Correlation analysis of volatile compounds and sensory profiles in Indonesian palm sugar (Arenga pinnata)Food Chemistry Advances · 2026
- A low-cost room-temperature electronic nose prototype for gas sensor characterization and simulated breath analysisMeasurement Science and Technology · 2026
- Comparative evaluation of computer vision and electronic nose technologies for quality classification of cardamom powder using machine learning approachesApplied Food Research · 2026
- Methodological Assessment of PDMS Passive Sampling for Skin VOC Collection Across Body Sites.Metabolites · 2026