Development and Preliminary Analytical Evaluation of a Portable Electronic-Nose Method for Discriminating Cassia grandis-Enriched Rice Beverages Using Chemometrics and HS-SPME-GC-MS
Víctor Manrique Fernández, Daniel Martín Vertedor, Francisco Pérez-Nevado, Jesús Lozano Rogado, Ismael Montero Fernández
Key points
From the paper's conclusion- This study presents the development and preliminary analytical evaluation of a portable electronic nose (E-nose) for differentiating rice-based beverages containing 0, 5, 10, and 20% (w/v) Cassia grandis pulp.
Abstract
This study presents the development and preliminary analytical evaluation of a portable electronic nose (E-nose) for differentiating rice-based beverages containing 0, 5, 10, and 20% (w/v) Cassia grandis pulp. The system was evaluated through optimization of the operating conditions, assessment of short-term repeatability and robustness, exploratory chemometric analysis, and complementary volatile characterization by headspace solid-phase microextraction coupled with gas chromatography–mass spectrometry (HS-SPME-GC-MS). The optimized conditions comprised a sample volume of 20 mL, a headspace equilibration time of 10 min, an adsorption period of 60 s, and a desorption period of 30 s. Under these conditions, the sensor responses exhibited relative standard deviations (RSDs) ranging from 1.88 to 3.67% during ten consecutive measurements. Robustness experiments involving deliberate variations in the operating parameters yielded RSDs between 0.87 and 2.48%, although reducing the desorption time to 20 s decreased the mean sensor response by 5.29%. Three independent beverage preparations were produced for each formulation, and ten E-nose measurements were obtained per formulation, resulting in 40 instrumental measurements. Principal component analysis (PCA) accounted for 96.18% of the total variance in the first two components (PC1: 87.04%; PC2: 9.14%) and revealed differences in sensor-response patterns among formulations. The control (A0) and the formulation containing 20% C. grandis pulp (A20) occupied distinct regions of the PCA space, whereas A5 and A10 exhibited greater similarity. Complementary HS-SPME-GC-MS analysis revealed formulation-dependent differences in chromatographic peak areas, particularly for terpene-related compounds. For example, the linalool peak area increased from 18.34 × 106 in A0 to 535.50 × 106 arbitrary units in A20. Nevertheless, preparation-grouped cross-validation and independent predictive validation could not be established from the available experimental records.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Study of Key Aroma Components in Rice of Different Aroma Types Using Flavor MetabolomicsFoods · 2026
- Electronic Nose Technology for Tea Quality Control, from Current Applications to Intelligent Manufacturing Prospects.Sensors (Basel, Switzerland) · 2026
- Effects of Different Processing Methods on the Flavor of Perilla frutescens var. crispa Based on Electronic Nose, Electronic Tongue, and Gas Chromatography–Ion Mobility SpectrometryFoods · 2026
- Multidimensional characterization of vegetable breads using multisource intelligent sensory technologies and feature-level data fusion.Frontiers in nutrition · 2026
- Complementary spectral and volatile fingerprints enable discrimination of post-harvest processed arabica coffee using NIR spectroscopy and HS-GC-IMS.Food chemistry · 2026
- Comparative evaluation of computer vision and electronic nose technologies for quality classification of cardamom powder using machine learning approachesApplied Food Research · 2026