Electrical Engineering in Japan

A Protection Method for DC Faults Using a Half‐Bridge MMC With Consolidated Arm Inductors in HVDC Transmission Systems for Offshore Wind Farms

Keima Wakatsuki, Kenichiro Sano, Takuya Kajiyama

Key points

From the paper's conclusion
  • Therefore, it is applicable to asymmetrical monopole and bipolar configurations.

Abstract

This paper proposes a new protection method for offshore terminals in HVDC transmission systems connecting offshore wind farms to onshore AC grids, specifically focusing on DC faults. The conventional single‐arm short protection method allows a half‐bridge modular multilevel converter (HB‐MMC) to suppress the fault current to zero without external devices. However, this method is effective only for pole‐to‐ground faults in symmetrical monopole configurations and cannot handle pole‐to‐pole faults in asymmetrical monopole or bipolar configurations. The proposed method employs an HB‐MMC with arm inductors consolidated into a single arm. By performing the single‐arm short protection, this converter can suppress fault currents to zero for both pole‐to‐pole and pole‐to‐ground faults. Therefore, it is applicable to asymmetrical monopole and bipolar configurations. The validity of the proposed method is verified by simulations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Protection Method for DC Faults Using a Half‐Bridge MMC With Consolidated Arm Inductors in HVDC Transmission Systems for Offshore Wind Farms — Science Skim