Interobserver Reliability of the Rotterdam Diabetic Foot Study Test Battery for Assessing Cutaneous Sensibility.
Nadine Boers, Isabelle M L P Kamm, Manuel Castro Cabezas, T M Fakkel, Willem D Rinkel, J Henk Coert
Department of Plastic, Reconstructive, and Hand Surgery, Utrecht University Medical Center, Utrecht, the Netherlands. · Department of Internal Medicine/Center for Diabetes, Endocrinology, and Vascular Medicine, Franciscus Gasthuis & Vlietland Hospital, Rotterdam, the Netherlands.
Key points
From the paper's conclusion- Both instruments showed good reproducibility in sensory staging, although this varied using scoring approach and analysis level. The dichotomous test batteries showed good reliability at the sum-score level, whereas exact agreement for the continuous 39-item test battery and reliability of several individual items were limited. Clinical use and ulcer risk classification require further evaluation before routine implementation.
Abstract
AIM: The Rotterdam Diabetic Foot (RDF) Test Battery was developed to assess sensory function and predict the risk of diabetic foot ulceration and falls. We evaluated its interobserver reliability in patients with diabetic sensorimotor polyneuropathy. METHODS: The RDF Test Batteries include a continuous and dichotomous 39-item scale and a shorter dichotomous 13-item scale. The 39-item test battery was administered by two investigators, and the 13-item test battery by five investigators with varying experience. Percentage agreement, Cohen's kappa coefficient (κ) and intraclass correlation coefficient (ICC) were calculated, including agreement in ulcer risk classification based on predefined cut-off values derived from the 39-item and 13-item test battery sum scores; incident ulcer outcomes were not collected. RESULTS: The continuous 39-item test battery (n = 36 test batteries) showed low to high exact agreement (33.9%-100%), poor item-level ICCs (0.04-0.19), and small median between-observer differences. Dichotomous 39-item (n = 56) and 13-item test batteries (n = 310) showed low percentage agreement (42.9% and 47.1%) but good reliability (ICC 0.83, 95% CI: 0.67-0.92 and 0.80, 95% CI: 0.73-0.85). Cut-off based classification of ulcer risk of the 39-item and 13-item test batteries showed acceptable to high agreement (96.4% and 87.1%) and substantial reliability (κ = 0.67 and 0.73, both p < 0.001). CONCLUSION: Both instruments showed good reproducibility in sensory staging, although this varied using scoring approach and analysis level. The dichotomous test batteries showed good reliability at the sum-score level, whereas exact agreement for the continuous 39-item test battery and reliability of several individual items were limited. Clinical use and ulcer risk classification require further evaluation before routine implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reproducibility of ACT, A simple-self-administered sCreening Tool for diabetic peripheral neuropathy.Frontiers in neurology · 2026
- Offloading Matters: A Meta-Research Audit of Mechanical Validity in Trials Supporting the 2023 IWGDF Recommendations on Interventions to Enhance Healing of Foot Ulcers in People with DM.The international journal of lower extremity wounds · 2026
- Evaluating the Quality of Reporting in Randomized Controlled Trial Abstracts on Diabetic Foot: A Cross-Sectional Study with Interrupted Time-Series Analysis.Biomedicines · 2026
- Reliability and validity of the Turkish version of the instrument of self-care for prevention of diabetic foot.Journal of tissue viability · 2026
- The Effect of Reflexology on Neuropathic Pain and Quality of Life in Diabetic Individuals: A Randomized Controlled Clinical StudyInternational Journal of Clinical Practice · 2026
- From Bench to Bedside: Evaluating the Accuracy of Clinical Sensory Testing in Detecting Somatosensory Disorders. A Systematic ReviewMusculoskeletal Care · 2026