Transulnar Access With Ipsilateral Radial Artery Occlusion for Percutaneous Coronary Procedures: Results From the ULNAR RAO Study.
Biljana Zafirovska, Aleksandar Jovkovski, Ivan Vasilev, Hajber Taravari, Danica Petkoska, Jorgo Kostov, Kalon K L Ho, Sasko Kedev
National Center for Cardiovascular Diseases, University Clinic of Cardiology, Faculty of Medicine, University of St. Cyril & Methodius, Skopje, North Macedonia. · Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA.
Key points
From the paper's conclusion- Ipsilateral TUA in patients with RAO is safe and successful when performed at experienced radial centers.
Abstract
AIMS: To evaluate the safety of transulnar artery access (TUA) in patients with ipsilateral radial artery occlusion (RAO). MATERIALS AND METHODS: Between March 2011 and December 2021, 1756 consecutive patients with RAO underwent percutaneous angiographic procedures via ipsilateral TUA in a high-volume radialist center. All patients were assessed for procedural safety. A more detailed analysis was performed on the last 103 consecutive patients with anatomical, functional, and pain assessment of the punctured arm, at baseline and up to 1 year of follow-up. Functional assessment was performed using a hydraulic hand dynamometer for hand strength and self-assessment with the QUICK-DASH questionnaire. A visual analog scale was used for pain assessment. Ulnar artery (UA) patency was evaluated clinically and by duplex ultrasound. UA diameter was measured using quantitative angiography and compared with previous forearm angiograms obtained before documentation of RAO. RESULTS: All 1756 TUA procedures were performed without clinical or ischemic hand complications, with a median follow-up of 83 months [IQR 56-108]. In the more intensively evaluated group of 103 patients (mean age 62.9 ± 9.0 years, 30% females), primary puncture success was 96.1%, with 3.9% requiring crossover to left radial access. Dynamometer assessment found a numerically small, transient reduction in grip strength, observed 12-24 h after procedure (72.6 ± 23.0 before vs.71.9 ± 23.0 lbs post-procedure), with subsequent recovery. QUICK-DASH scores remained unchanged during follow-up. No UA occlusion was detected. UA diameter increased following RAO by 0.28 ± 0.35 mm (p < 0.0001). CONCLUSION: Ipsilateral TUA in patients with RAO is safe and successful when performed at experienced radial centers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transulnar access in patients with ipsilateral radial artery occlusion undergoing coronary angiography or angioplasty: 24-hour clinical and quantitative outcomes from the ULNART studyEuropean Heart Journal · 2026
- Early Ulnar Artery Occlusion and Recanalization After Coronary Angiography via Distal Ulnar Access: A Doppler-Followed Case Series.Angiology · 2026
- Reverse Barbeau test accuracy in the diagnosis of radial artery occlusion after transradial coronary catheterizationEuropean Heart Journal · 2026
- Radial artery occlusion in transradial coronary catheterization: incidence and prognostic factorsEuropean Heart Journal · 2026
- Repeated transradial coronary procedures: ultrasound-validated incidence of symptomatic radial artery occlusionEuropean Heart Journal · 2026
- Ulnar Artery Aneurysm with Ipsilateral Radial Artery Occlusion: A Case Report and Literature Review.Vascular specialist international · 2026