Reverse Barbeau test accuracy in the diagnosis of radial artery occlusion after transradial coronary catheterization
A Keramas, S Tsokkou, A Pagiantza, A S Papazoglou, C Kakderis, S Daios, E Peteinidou, K Lekka,
Key points
From the paper's conclusion- Implementing universal reverse Barbeau screening, followed by targeted ultrasound only in abnormal cases, may offer a practical and efficient strategy for early detection and follow-up of RAO after transradial coronary procedures.
Abstract
Background Radial artery occlusion (RAO) is a relatively common consequence of transradial coronary procedures, yet it often goes unnoticed because patients remain asymptomatic. Despite its relevance for future access sites and potential graft use, routine evaluation of radial artery patency before hospital discharge is not consistently practiced. Purpose This study examined how accurately an early bedside reverse Barbeau test (pulse oximetry plethysmography) can identify RAO when compared with radial artery duplex ultrasound performed at the same time point. Methods A total of 769 patients undergoing transradial coronary angiography or angioplasty were enrolled. In the first 24 hours after successful hemostasis (T0), each participant underwent a reverse Barbeau test, categorized as either normal (types A, B, C) indicative of radial artery patency or abnormal (type D) indicative of RAO. Radial artery patency was simultaneously assessed with duplex ultrasound, which served as the reference standard. The primary outcome was the presence of RAO on ultrasound at T0. Diagnostic metrics, including sensitivity, specificity, positive and negative predictive values, and likelihood ratios, were calculated. Results Complete paired assessments were available for 724 individuals. Ultrasound confirmed RAO in 69 patients (9.5%). An abnormal reverse Barbeau test occurred in 70 cases (9.7%), 58 of which corresponded to true RAO. The test demonstrated a sensitivity of 84.1% and a specificity of 98.2%. The positive predictive value reached 82.9%, while the negative predictive value was 98.3%. The positive likelihood ratio was 45.9, and the negative likelihood ratio was 0.16. Among those with RAO at T0, spontaneous recanalization was observed in 12.3% at four weeks, and either full or partial improvement in patency occurred in 25.4%. Conclusion An early reverse Barbeau test performed at the bedside shows high specificity and an excellent ability to rule out RAO when compared with ultrasound. Implementing universal reverse Barbeau screening, followed by targeted ultrasound only in abnormal cases, may offer a practical and efficient strategy for early detection and follow-up of RAO after transradial coronary procedures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Repeated transradial coronary procedures: ultrasound-validated incidence of symptomatic radial artery occlusionEuropean Heart Journal · 2026
- Radial artery occlusion in transradial coronary catheterization: incidence and prognostic factorsEuropean Heart Journal · 2026
- Pressure-guided pneumatic radial compression and radial artery occlusion after transradial coronary procedures: a retrospective historical cohort study.Scandinavian cardiovascular journal : SCJ · 2026
- Prevention of radial artery occlusion with rivaroxaban after interventional coronary interventions using transradial access: Results of a single-center randomized clinical trial.The journal of vascular access · 2026
- Transulnar access in patients with ipsilateral radial artery occlusion undergoing coronary angiography or angioplasty: 24-hour clinical and quantitative outcomes from the ULNART studyEuropean Heart Journal · 2026
- Sonographic Diagnosis and Anatomic Mapping of a Radial Artery Pseudoaneurysm Following Transradial Cardiac Catheterization.Journal of clinical ultrasound : JCU · 2026