Quantitative Measurement of Hoover's Sign: Development of a Standardized Sensor, Interface Procedure, and Testing in Healthy Individuals.
Takamichi Kanbayashi, Adarsh Nigam, Ciara Pletcher, Alexander White, Srinjoy Mitra, Jon Stone
Department of Neurology, Teikyo University School of Medicine, Itabashi-ku, Tokyo, Japan. · School of Engineering, The University of Edinburgh, Edinburgh, UK.
Key points
From the paper's conclusion- This portable device can provide a standardized quantitative measure of Hoover's sign and may be useful in future studies of functional leg weakness, particularly in patients with comorbid conditions.
Abstract
BACKGROUND: Hoover's sign is a commonly used clinical sign for diagnosing functional leg weakness, a feature of functional neurological disorder (FND). However, it relies on clinicians' qualitative assessment. Therefore, more reliable and objective assessment methods are needed. This study aims to develop a portable device and procedure for standardized quantitative measurement of Hoover's sign and validate its utility in healthy controls feigning leg weakness. METHODS: Healthy volunteers without medical backgrounds were recruited. A portable floor-based device with a pressure sensor placed under the heel of one foot was developed to measure hip extension strength during voluntary and involuntary movements. Subjects performed the test under three conditions: healthy, feigning mild weakness, and feigning severe weakness. The involuntary/voluntary ratio (IV/V ratio) and the side ratio (the IV/V ratio of the feigning leg compared to the non-feigning leg) were evaluated. RESULTS: Forty-two subjects were recruited. In the healthy state, the mean IV/V ratio was 0.60 ± 0.23 on the right side and 0.62 ± 0.24 on the left. The IV/V ratio was significantly higher in the feigned leg during both mild (1.26 ± 0.49) and severe (1.83 ± 0.70) feigning compared to the healthy state (p < 0.001 for both), while it was significantly lower in the non-feigned leg during mild (0.40 ± 0.22) and severe (0.32 ± 0.22) feigning (p < 0.001 for both). The side ratio also significantly increased during feigning. ROC analysis revealed optimal IV/V ratio cutoffs of 0.93 for distinguishing mild feigning (sensitivity: 77%, specificity: 93%), and 0.95 for severe feigning (sensitivity: 91%, specificity: 94%). CONCLUSIONS: This portable device can provide a standardized quantitative measure of Hoover's sign and may be useful in future studies of functional leg weakness, particularly in patients with comorbid conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hoover's Test Revisited.Muscle & nerve · 2026
- TP8.1 A Visual Analog Scale for Single-Leg Squat Assessment Demonstrates Reliability in Patients with Hip PathologyJournal of Hip Preservation Surgery · 2026
- Measurement Properties of Hand‐Held Dynamometry for Ankle Strength Assessment: A COSMIN‐Based Systematic Review and Meta‐AnalysisMusculoskeletal Care · 2026
- Reliability and measurement error of hip abductor muscle strength using a hand-held dynamometer in healthy adults.Journal of physical therapy science · 2026
- Clinical examination findings were not associated with isometric strength or functional performance in adults with groin pain.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2026
- Agreement Between Handheld and Fixed Dynamometry for Hip Strength Assessment in Young Soccer Players and Non-Soccer Controls: An Exploratory Study.Journal of clinical medicine · 2026