Agreement Between Handheld and Fixed Dynamometry for Hip Strength Assessment in Young Soccer Players and Non-Soccer Controls: An Exploratory Study.
Rafał Borkowski, Jakub Grodzki, Patrycja Adamska
Faculty of Rehabilitation, The Józef Piłsudski University of Physical Education in Warsaw, Marymoncka 34, 00-968 Warsaw, Poland.
Key points
From the paper's conclusion- This exploratory cross-sectional study compared measurements of hip adductor and abductor strength obtained using a handheld dynamometer (DynaMo) and an externally fixed dynamometer (ForceFrame) in young soccer players and non-soccer controls.
Abstract
Background/Objectives: Handheld dynamometers are increasingly used for muscle strength assessment because of their low cost, portability, and ease of implementation in clinical and sports settings. However, it remains unclear whether measurements obtained using handheld and externally fixed dynamometers can be used interchangeably in young soccer players. This exploratory cross-sectional study compared measurements of hip adductor and abductor strength obtained using a handheld dynamometer (DynaMo) and an externally fixed dynamometer (ForceFrame) in young soccer players and non-soccer controls. Methods: Forty healthy men (20 U-21 soccer players and 20 non-soccer controls) were included. Isometric hip adduction and abduction strength were assessed bilaterally using DynaMo and ForceFrame during a single testing session. Agreement between measurement methods was evaluated using Bland-Altman analysis, and associations between methods were determined using Spearman's rank correlation coefficients. Results: Moderate to very strong positive correlations were observed between DynaMo and ForceFrame measurements (r = 0.44-0.96), although the correlation for left hip abduction in soccer players did not reach statistical significance (p = 0.052). Nevertheless, Bland-Altman analysis revealed a systematic bias, with ForceFrame producing higher normalized hip strength values than DynaMo across all assessments. The mean bias ranged from 2.02 to 3.34 N/kg (95% LoA 0.21 to 4.83 N/kg) in the soccer group, and 0.92 to 2.00 N/kg (95% LoA 0.18 to 2.93 N/kg) in the non-soccer group. Conclusions: Although moderate to very strong correlations were observed between the two dynamometry systems, systematic differences in recorded strength values indicate that the two systems may not be considered directly interchangeable for assessing hip abductor and adductor strength. For longitudinal monitoring and clinical decision-making, repeated assessments should preferably be performed using the same measurement system, and caution is warranted when interpreting absolute hip muscle strength values. Given the exploratory design and relatively small sample, these findings should be interpreted cautiously and confirmed in larger studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Measurement Properties of Hand‐Held Dynamometry for Ankle Strength Assessment: A COSMIN‐Based Systematic Review and Meta‐AnalysisMusculoskeletal Care · 2026
- Handgrip Strength and Isokinetic Knee Extensor and Flexor Torque in Adolescent Soccer Players.Muscles (Basel, Switzerland) · 2026
- Reliability and measurement error of hip abductor muscle strength using a hand-held dynamometer in healthy adults.Journal of physical therapy science · 2026
- Shoulder Internal and External Rotator Strength Reliability and Validity in Healthy Adolescent Athletes.International journal of sports physical therapy · 2026
- Impact of Correcting for Pelvic Tilt on the Assessment of Concentric Hip Extension Torque: Validity and Reliability of Isokinetic DynamometryScandinavian Journal of Medicine and Science in Sports · 2026
- Portable Dynamometry Is Reliable for Measuring Knee and Ankle Strength in Daily Practice: Results From a Systematic Review With Meta-analysis and Evidence Gap Map Using the COSMIN Methodology.The Journal of orthopaedic and sports physical therapy · 2026