Simultaneous Quantification of Acetaminophen and Oxycodone in Human Plasma by UPLC‐MS/MS and Its Application to Pharmacokinetic Study of Single‐Dose and Multiple‐Dose Administrations
Wei‐ying Tang, Shan‐shan Yang, Yu‐tao Wei, Min Yang, Sha Li, Bo‐ping Wei, Qiang Wu, Heng‐yi Zhu
Key points
From the paper's conclusion- The intra‐ and inter‐day accuracy bias was in the range of −1.1% to 6.2% (RSD ≤ 6.3%).
Abstract
In this study, a novel ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method with high sensitivity, high efficiency, and easy operation was established and validated for the simultaneous quantification of acetaminophen (APAP) and oxycodone (OC) in human plasma. Sample preparation involved protein precipitation with acetonitrile, followed by nitrogen evaporation, and the separation was achieved by a Waters BEH column (2.1 mm × 50 mm, 1.7 μm) with a gradient elution using acetonitrile, ammonium acetate buffer, and formic acid as the mobile phase. The detection of APAP (m/z 152.1 → 110.2) and OC (m/z 316.0 → 241.2) was performed using multiple reaction monitoring (MRM) mode with positive electrospray ionization (ESI). APAP‐d3 (m/z 155.1 → 111.1) and OC‐d3 (m/z 319.2 → 244.2) were used as internal standards. The calibration curves showed good linear relationships over the concentration ranges of 0.0500–12.0 μg/mL for APAP and 0.100–24.0 ng/mL for OC, respectively, using a weighted (1/ x 2 ) linear regression model. The intra‐ and inter‐day accuracy bias was in the range of −1.1% to 6.2% (RSD ≤ 6.3%). Recovery, specificity, matrix effect, and stability were also assessed. This high‐throughput method was successfully applied to compare the pharmacokinetics of extended‐release and immediate‐release OC/APAP tablets in chronic pain patients and to evaluate the food effect on the extended‐release formulation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A robust liquid chromatography–tandem mass spectrometry method for accurate quantification of omeprazole in human plasma: Integration of International Council for Harmonisation guidelines for pharmacokinetic applicationActa Chromatographica · 2026
- Sustainable UHPLC-MS/MS assay for ultra-sensitive simultaneous quantification of amoxicillin and flucloxacillin with application to a bioequivalence study.Analytical and bioanalytical chemistry · 2026
- Determination of Apalutamide in Human Plasma by Sensitive LC‐MS/MS Method and the Application to a Bioequivalence StudyBiomedical Chromatography · 2026
- B-342 Long run LC–MS/MS robustness in human plasma: a 30,000-injection evaluation of quantitative stability, carryover, and uptime on a triple quadrupole platform for clinical researchClinical Chemistry · 2026
- Simultaneous UPLC-MS/MS determination of apalutamide, atorvastatin and their metabolites in rat plasma for pharmacokinetic interaction studies.Journal of pharmaceutical and biomedical analysis · 2026
- Development and Validation of an Ultra‐Fast UPLC–MS/MS Method for Simultaneous Quantification of Lodenafil and Lodenafil Carbonate in Human Liver Microsomes: Depletion Rate and Metabolic Stability AssessmentBiomedical Chromatography · 2026