Assessing predictive performance of four semi-mechanistic models for long-term HbA1c with dulaglutide in people with Type 2 diabetes.
Austin Yue Feng Tan, Karen Schneck, Parag Garhyan, Eric Chun Yong Chan, Lai San Tham
Department of Pharmacy and Pharmaceutical Sciences, National University of Singapore, Singapore, Singapore. · Eli Lilly and Company, Indianapolis, Indiana, USA.
Key points
From the paper's conclusion- The transit compartment models performed consistently well for dulaglutide and LY2409021, and therefore, they are preferred for describing glycaemic control for novel antidiabetic compounds with similar mechanisms of action. Fasting glucose is more convenient to measure than average glucose in the clinic setting, favouring the FHH model that utilized fasting glucose as its biomarker.
Abstract
AIM: Glycated haemoglobin (HbA1c) reflects the long-term glycemic control over at least 3 months in Type 2 diabetes. Predicting HbA1c using glucose data from studies of less than 3 months would be valuable. We previously evaluated four semi-mechanistic HbA1c models (ADOPT, FFH, FHH and IGRH) for their ability to predict HbA1c for the small molecule LY2409021, and the transit compartment models (FHH and IGRH) performed well. This work aims to evaluate HbA1c predictive performance of the four models for a long-acting therapeutic protein, dulaglutide. METHODS: The models were developed using dulaglutide concentrations, glucose and HbA1c data from a 5-week Phase 1b study. Model predictive performance was assessed by comparing model-estimated and observed HbA1c values from two Phase 2 and 3 studies. There were three metrics for predictive performance: (a) mean change from baseline HbA1c (ΔHbA1c) between observed and model-predicted values; (b) mean prediction error (MPE) for bias; and (c) root mean squared error (RMSE) for precision. RESULTS: Overall, all models predicted the mean ΔHbA1c closely, within 0.2% of the observed values for the Phases 2 and 3 studies, at Weeks 26, 36 and 52. All models exhibited little bias (absolute MPE < 0.3%) and comparable precision (RMSE = 0.385-0.507%) estimates. CONCLUSIONS: The transit compartment models performed consistently well for dulaglutide and LY2409021, and therefore, they are preferred for describing glycaemic control for novel antidiabetic compounds with similar mechanisms of action. Fasting glucose is more convenient to measure than average glucose in the clinic setting, favouring the FHH model that utilized fasting glucose as its biomarker.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Review of Semi-Mechanistic HbA1c Models in People with Type 2 Diabetes: Strengths, Limitations, and Applications.Journal of clinical pharmacology · 2026
- Prediction of Six-Month Glycemic Status in Type 2 Diabetes: Development and Internal Validation of a Multivariable Model.Diagnostics (Basel, Switzerland) · 2026
- Machine Learning Models for Glycemic Prediction in Type 1 and Type 2 Diabetes: Systematic Review and Meta-Analysis.Journal of medical Internet research · 2026
- Who Should Have an HbA1c? Development and External Validation of a Dysglycaemia Prediction Model Using Only Routinely Available Data.Healthcare (Basel, Switzerland) · 2026
- Updated glucose management indicator (GMI) better aligns with HbA1c than current GMI: implications for clinical practice and reportingDiabetologia · 2026
- Associations of Hemoglobin Glycation Index with Glucose Variability and Time in Ranges in Patients with Type 2 Diabetes Undergoing Continuous Glucose Monitoring.International journal of medical sciences · 2026