Thermal Stability and Combustibility Characterization of Aluminium Composite Panel Core Materials
Ashrul Riezal Asbar, Wan Nursheila Wan Jusoh, Muhd Zulfadhli Muhd Zaimi, Ahmad Faiz Tharima, Muhammad Imran Najeeb
Key points
From the paper's conclusion- Overall, the results show a clear ranking of A2 > FR > PE in terms of heat release, mass loss and residue, providing practical guidance for safer ACP core selection, although system‐level testing is still required for full panel assemblies.
Abstract
Aluminium composite panels (ACPs) are widely used as facade cladding, including in aerodrome buildings, because they are lightweight, weather‐resistant and easy to fabricate. However, the combustibility of their core materials has raised serious fire safety concerns. In this study, five commercial ACP cores commonly used in Malaysia, namely limited‐combustible (A2), fire‐retardant (FR1, FR2, FR3) and polyethylene (PE), were extracted from the panels and characterized using Energy Dispersive X‐Ray Fluorescence (EDXRF), Thermogravimetric Analysis (TGA), Cone Calorimetry (CCM) at 50 kW/m 2 and Scanning Electron Microscopy (SEM). EDXRF showed that A2 was dominated by calcium (75.7%), the FR cores contained lower calcium with notable aluminium, and the inorganic fraction of PE was mainly calcium, with smaller amounts of magnesium, titanium, aluminium and sodium. TGA showed that A2 retained 63.4% residue at 800°C, the FR cores 44.9–54.2%, and PE only 8.1%, indicating almost complete decomposition. In the CCM tests, PE ignited at 18.0 ± 1.7 s and reached a peak heat release rate (pHRR) of 684.4 ± 19.8 kW/m 2 , whereas A2 ignited at 60.7 ± 13.7 s with a pHRR of only 62.3 ± 16.6 kW/m 2 . The FR cores ignited between 34.0 and 63.0 s with pHRR values of 165.6–203.9 kW/m 2 , but continued flaming longer than both A2 and PE. SEM of the residues showed that A2 remained compact and intact, FR1 left a porous, partly fragmented residue, and PE left only a fragile, powdery residue. Overall, the results show a clear ranking of A2 > FR > PE in terms of heat release, mass loss and residue, providing practical guidance for safer ACP core selection, although system‐level testing is still required for full panel assemblies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fire Performance, Thermal Degradation and Combustion Products of Flame-Retardant Hybrid Epoxy Composites.Materials (Basel, Switzerland) · 2026
- Integrating ReaxFF-MD simulations into fire safety performance evaluation of polypropylene/ammonium polyphosphate compositesComposites Part A Applied Science and Manufacturing · 2026
- The Response of Flame-Retardant Polypropylene Composites After Long-Term Exposure to Corrosive Media.Polymers · 2026
- Sound absorption and flame retardancy properties of polyurethane foam composites with layered double hydroxidesJournal of Physics: Conference Series · 2026
- Dynamic Response of PVC Foam/Polyurea Sandwich Structures with Different Core Layers Under Air Blast Loading.Polymers · 2026
- Multi-Component Coatings Enabling Low-Toxicity and Self-Extinguishing Polyurethane Foams with Potential for Railway Fire Safety.Polymers · 2026