Fire Performance, Thermal Degradation and Combustion Products of Flame-Retardant Hybrid Epoxy Composites.
Kamila Mizera, Kamila Sałasińska
Central Institute for Labour Protection-National Research Institute (CIOP-PIB), Czerniakowska St. 16, 00-701 Warsaw, Poland.
Key points
From the paper's conclusion- This study investigates the effects of different combinations of synthetic and natural fabrics and functional fillers on the fire behavior, thermal degradation, smoke production, and combustion products of epoxy composites containing 10 wt.% expandable graphite (EG) and 10 wt.% ammonium polyphosphate (APP).
Abstract
The fire performance of hybrid epoxy composites depends on both the flame-retardant system and the reinforcement architecture. This study investigates the effects of different combinations of synthetic and natural fabrics and functional fillers on the fire behavior, thermal degradation, smoke production, and combustion products of epoxy composites containing 10 wt.% expandable graphite (EG) and 10 wt.% ammonium polyphosphate (APP). A glass-fiber-reinforced composite was used as the reference. The materials were characterized by cone calorimetry, smoke density measurements, horizontal burning tests, thermogravimetric analysis (TG/DTG), differential scanning calorimetry (DSC), simultaneous thermal analysis coupled with Fourier-transform infrared spectroscopy (STA/FT-IR), and combustion-effluent analysis using a Purser furnace coupled with a Gasmet DX4000 gas analyzer. Significant differences in fire performance were observed among the formulations. VACMGBHF exhibited the longest time to ignition (206 s), the lowest peak heat release rate (79 kW·m-2), and the lowest maximum mass-loss rate during the principal thermo-oxidative degradation stage (2.03%·min-1). It also retained 38.8% of its initial mass at 900 °C, the highest value among the hybrid composites. In contrast, ACGBF showed the lowest average heat release rate (8 kW·m-2), maximum average rate of heat emission (20 kW·m-2), and total heat release (4 MJ·m-2). Smoke production also depended on composite composition. The lowest maximum specific optical density was recorded for the glass-fabric reference (42), whereas ACGBF exhibited the lowest total smoke release (123 m2·m-2). Visual examination revealed differences in the continuity and morphology of the post-combustion residues, with several hybrid formulations forming expanded, cohesive carbonaceous-mineral layers. TG/DTG, DSC, and STA/FT-IR analyses further demonstrated formulation-dependent degradation behavior and evolved-gas profiles. All composites achieved the HB classification in the horizontal burning test. The findings demonstrate that reinforcement architecture and filler composition influence heat release, smoke generation, and thermal stability in different ways, highlighting the need to evaluate these parameters together when designing flame-retardant epoxy composites.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of Intrinsically Flame-Retardant and Bio-Based Fiber-Reinforced Polymer Composite Using a Furan-Based Epoxy and Flax FibersFibers · 2026
- Fire Performance and Flame‐Retardant Behavior of Epoxy Resin Modified With Fly Ash and Aluminum TrihydrateApplied Research · 2026
- Mg, Si, Al, and P Particle-Doped Epoxy: A Synergistic Approach for Enhanced Fire PerformanceEmerging Science Journal · 2026
- Bio-inspired interfacial engineering of carbon fabric@ZIF-67@cobalt phytate towards enhanced fire safety and mechanical properties of epoxy compositesAdvanced Composites and Hybrid Materials · 2026
- Tailoring the Fire-Retardant Efficacy of Intumescent Coatings via Optimal Selection of Epoxy Binder Molecular Weight.Polymers · 2026
- Engineering Phosphorus–Iron Coordination Complexes for Simultaneously Fire‐Retardant and Enhanced Epoxy ResinsSafety Science and Technology · 2026