High‐Strain Characterization of Polycrystalline Sputtered Vanadium Dioxide Resistors on Polyimide Membranes
Loïc Lahaye, Denis Flandre, Jean‐Pierre Raskin
Key points
From the paper's conclusion- This showcases the limits of p‐ for strain sensing passed 0.1% deformation, highlighting the importance of grain boundary dislocations occurring in the material.
Abstract
This paper demonstrates the continuous and exponential increase of the gauge factor of strained polycrystalline vanadium dioxide (p‐) resistors. The devices are integrated on a 2.5 ‐thick polyimide membrane using a monolithic processing scheme. The membrane is assembled on a bulge‐test setup, and pressure cycles up to 100 kPa are applied. The deflection profile of the pressurized membrane is measured to calibrate an FEM Comsol model. The model is used to recover the strain field in the p‐ devices. A biaxial tensile strain of 0.3% is reached. IV measurements are performed at each pressure step. An exponential increase in resistance is observed with a variation of 145% at 0.3% strain. Cycling of the pressure shows that permanent defects are induced in the p‐ for strain above 0.1%. The resistance variation follows a hysteresis while subjected to increasing and decreasing strain. When strained to 0.3%, a 10% permanent resistance decrease is observed. The gauge factor is extracted from the IV measurements and showcases a continuous and exponential variation up to 4180 at 0.2% of strain. This showcases the limits of p‐ for strain sensing passed 0.1% deformation, highlighting the importance of grain boundary dislocations occurring in the material.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Decoupling Gauge Factor and Baseline Resistance Through Crack-Percolation Hybrid Design for Flexible Multimodal Strain Sensors.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Numerical Investigation of Piezoresistive Materials and Sensor Geometry for Enhanced Sensitivity and Reduced Structural Nonlinearity in Microelectromechanical Systems Pressure Sensors for In Vivo Biomedical Applicationsphysica status solidi (a) · 2026
- Electroforming in VO₂ Switch: Phase Transformation and Electromigration PhenomenaACS Nano · 2026
- Vapor-induced porosity in graphene/PDMS: a scalable route to high-performance pressure sensorsMicrosystems & Nanoengineering · 2025
- Thickness-dependent structural and hysteretic properties of pld-grown VO2 thin films on glass substratePhysica Scripta · 2026
- Mechanical Stability of Amorphous Silicon Thin-Film Devices on Polyimide for Flexible Sensor PlatformsSensors · 2026