Decoupling Gauge Factor and Baseline Resistance Through Crack-Percolation Hybrid Design for Flexible Multimodal Strain Sensors.
Seungyeob Kim, Hyeon Bin Jo, Seongyeop Kim, Won Young Lee, Sanghun Jeon, Sung Hun Jin
School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Republic of Korea. · Department of Information Display, Kyung Hee University, Seoul, Republic of Korea.
Key points
From the paper's conclusion- These results define a new framework for strain sensing with independent control of electrical and mechanical responses, with broad implications for flexible and bio‐integrated electronic systems.
Abstract
Flexible strain sensors for wearable systems, soft robotics, and distributed electronics exhibit a coupling between gauge factor (GF) and baseline resistance (R0), as both depend on a structural parameter, limiting independent control of sensitivity and electrical characteristics. Here, a single-walled carbon nanotubes (SWNT)/SU-8/cracked-polydimethyl-siloxane (PDMS) (SSC) platform is introduced to decouple GF and R0 through two independent fabrication parameters. Pre-strain (0-4%) defines closable cracks in a SU-8/PDMS bilayer, setting GF (0.1-100), while the spray volume of a 0.1 wt% SWNT dispersion (1-3 mL) controls R0 from ∼10 kΩ to >1 MΩ through network percolation. Finite-element and Monte Carlo analyses indicate that the large GF originates from stochastic changes in conductive pathways within sparse SWNT networks bridging dynamically closing cracks, rather than from crack geometry alone. The platform is demonstrated in IGZO thin-film transistor-based strain-to-frequency converters (0.67-1.9 MHz over 0-3% strain), μ-LED modulation, broadband vibration sensing (82.4-329.6 Hz), and wearable bio-logging modules. As an application, the system detects ultra-slow respiration in anesthetized large mammals (lynx: 22-23 BPM; tiger: 2-3 BPM), where conventional monitors show limited sensitivity. These results define a new framework for strain sensing with independent control of electrical and mechanical responses, with broad implications for flexible and bio-integrated electronic systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bio-Inspired Gradient Heterogeneous Architectures for Ultrasensitive and Robust Strain Sensors via Programmable Crack Engineering.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- Enhanced Sensitivity in Crack-Based Graphene Nanoplatelets Strain SensorsACS Applied Materials & Interfaces · 2026
- Flexible Strain Sensor Based on TPU/CNTs/rGO Conductive Membrane with Dual-Microcrack Structure for High-Performance Wearable Sensing.Nanomaterials (Basel, Switzerland) · 2026
- Hook-and-Loop-Inspired CNTs/CNFs Structure for Flexible Strain Sensors With Ultra-High Sensitivity and Wide Sensing Range.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Bioinspired Ion‐Riveted Double‐Layer Carbon Nanotube Coating Enables Crack‐Gated Impedance Amplification in Hydrogel Strain SensorsAdvanced Functional Materials · 2026
- Ultra‐Broad Range and High Sensitivity Flexible Pressure Sensing Enabled by Hierarchical Microstructure With Multi‐Path Conduction MechanismsEcoMat · 2025