CrystaL Artificial Intelligence Monitoring (CLAIM) Study of the OMERACT Ultrasound CPPD Subtask Working Group: Interim Analysis of Automated Ultrasound Grading of Knee Meniscal CPPD.
Marco D Dal Fabbro, Tito Bassani, Daniele Cirillo, Rodolfo Fabbri, Alessandro Lucia, Laura Pezzoni, Luca Ingrao, Antonella Adinolfi,
Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Milan, Italy. · Laboratory of Biological Structures Mechanics, IRCCS Galeazzi - Sant'Ambrogio Hospital, Milan, Italy.
Key points
From the paper's conclusion- These findings provide a methodological basis for automated CPPD US grading, but performance remains far from clinical applicability, highlighting the need for larger datasets and improved segmentation.
Abstract
OBJECTIVE: We aimed to develop and evaluate artificial intelligence (AI)-based methods for automated grading of calcium pyrophosphate deposition (CPPD) in ultrasound (US) images according to the Outcome Measures in Rheumatology (OMERACT) US scoring system. METHODS: Within the OMERACT CrystaL Artificial Intelligence Monitoring (CLAIM) project, two deep learning strategies were explored using knee meniscus US images graded from 0 to 3. Image-level classification was evaluated using convolutional neural networks (CNN) trained directly on cropped meniscus images (n = 446). A semantic segmentation approach was developed using a subset of 279 images with manually annotated masks identifying meniscus and deposits. Models were evaluated using an 80/20 training-validation split and stratified 5-fold cross-validation. Segmentation was assessed using Intersection over Union (IoU). For automated grading, an area ratio (AR), representing CPPD pixels relative to meniscus and CPPD pixels, was applied to predicted masks. RESULTS: Image-level classification achieved an accuracy of 0.69 in the single-split analysis and a mean accuracy of 0.59 (SD 0.10) in 5-fold cross-validation. End-to-end AR grading achieved accuracies of 0.64 and 0.61 (SD 0.10), with a grade 3 recall of 0.25 in the single split. AR grading on manually annotated reference masks achieved an accuracy of 0.82. The best-performing segmentation model achieved mean IoUs of 0.86 for background, 0.60 for meniscus, and 0.37 for CPPD. CONCLUSIONS: These findings provide a methodological basis for automated CPPD US grading, but performance remains far from clinical applicability, highlighting the need for larger datasets and improved segmentation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial intelligence-based segmentation and quantitative assessment of knee cartilage in osteoarthritis: a systematic review and meta-analysis.International orthopaedics · 2026
- Artificial intelligence-based grading of human cataracts: A feasibility study.PloS one · 2026
- Multi-Granularity Mask-Guided Network: An Integrated AI Framework for Region-Level Segmentation and Grading of Cataract Subtypes on AS-OCT ImagesJournal of Clinical Medicine · 2026
- Clinical Validation of Artificial Intelligence (AI)-based Cartilage Segmentation Predicting Knee Replacement.Arthritis care & research · 2026
- Development, Evaluation, and Multicenter Clinical-Trial Application of an Artificial Intelligence-Assisted MRI Method for Quantitative Knee Cartilage MorphometryarXiv · 2026
- Automated quantitative computed tomography grading of lumbar facet joint degeneration: influence of segmentation errors on instance-level clinical assessment.Quantitative imaging in medicine and surgery · 2026