Development, Evaluation, and Multicenter Clinical-Trial Application of an Artificial Intelligence-Assisted MRI Method for Quantitative Knee Cartilage Morphometry
Binbin Yang, Rui Huang, Yuanjing Xu, Jingshu Wu, Chengzhang He, Yinan Chen, Qi Duan
Key points
From the paper's conclusion- Objective: To develop and evaluate an AI-assisted MRI method for quantitative knee cartilage morphometry in a multicenter phase III knee osteoarthritis trial.
Abstract
Objective: To develop and evaluate an AI-assisted MRI method for quantitative knee cartilage morphometry in a multicenter phase III knee osteoarthritis trial. Methods: AI pre-segmentation used 3D full-resolution nnU-Net. Version 1.0 used separate femorotibial- and patellar-cartilage models, whereas version 2.0 used a unified three-class model trained on gold-standard annotations. Trial images then underwent two-reader correction and third-reader adjudication. Adjudicated masks were partitioned into medial/lateral femoral and tibial cartilage plus patellar cartilage. Cartilage volume was measured in physical coordinates, mean thickness by 3D ray tracing (3D-RT), and surface area with local thickness <1.5 mm by a 3D ray-based area method (3D-RBA). Evaluation included 1,189 phase III MRI examinations, reader agreement, 20 synthetic thinning models, and a 69-participant longitudinal comparison with 3D-PMA and three comparator thickness methods. Results: Overall pre-segmentation Dice was 0.964 +/- 0.030 (median 0.970), with 78.7% achieving Dice >=0.95. Inter-reader ICCs for cartilage volume were 0.959-0.995. In the 69-participant subset, total cartilage volume increased from 14,184.366 mm^3 at V0 to 15,359.345 mm^3 at V8; 3D-RBA and 3D-PMA decreased by 4.70% and 6.88%, and all four thickness measures were highest at V8. In 20 geometric experiments, MAPE was 5.73%, CCC 0.822, and Dice 0.956. The workflow was applied to 1,188 MRI examinations from 416 participants. From V0 to V8, the treatment group showed +3.45% total cartilage volume, +2.46% mean thickness, and -4.54% 3D-RBA, versus -2.08%, -1.32%, and +0.16% in controls. Conclusion: This workflow provided a reproducible MRI cartilage assessment framework for a multicenter KOA trial. Cross-method agreement and geometric validation supported 3D-RT and 3D-RBA for therapeutic efficacy evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial intelligence-based segmentation and quantitative assessment of knee cartilage in osteoarthritis: a systematic review and meta-analysis.International orthopaedics · 2026
- Clinical Validation of Artificial Intelligence (AI)-based Cartilage Segmentation Predicting Knee Replacement.Arthritis care & research · 2026
- CLINICAL VALIDATION OF ARTIFICIAL INTELLIGENCE (AI)-BASED CARTILAGE ANALYSIS PREDICTING KNEE REPLACEMENT (KR).Osteoarthritis imaging · 2026
- A memory based model for cartilage and meniscus segmentation in 3D knee MRIScientific Reports · 2025
- Advancing deep learning based knee cartilage segmentation in MRI: Innovations, challenges and applicationsOsteoarthritis and Cartilage Open · 2025
- Distinct 3‐Dimensional Anatomic Patterns Including Flatter Surfaces and Greater Sagittal Inclinations of Intra‐articular Structures Are Reliably Identified Through an Artificial Intelligence‐Based Pipeline in Anterior Cruciate Ligament‐Injured KneesArthroscopy The Journal of Arthroscopic and Related Surgery · 2026