Deep learning-based dose prediction for stereotactic prostate cancer radiotherapy with CyberKnife.
Hilla Magga, Henri Korkalainen, Tuomas Virén, Janne Heikkilä, Jan Seppälä, Akseli Leino
Department of Technical Physics, University of Eastern Finland, Kuopio, Finland. · Center of Oncology, Kuopio University Hospital, Kuopio, Finland.
Key points
From the paper's conclusion- A U-Net-based convolutional neural network framework is developed for predicting dose distributions in CyberKnife prostate cancer radiotherapy.
- The model achieved a mean absolute error of 0.63 Gy for the rectum and 1.04 Gy for the bladder in the independent test set.
- The proposed model may provide patient-specific dose estimates for setting initial planning objectives to assist in automating treatment planning.
Abstract
BACKGROUND: Deep learning-based (DL) approaches have gained interest in predicting dose distributions in radiotherapy of prostate cancer treated with volumetric modulated arc therapy and intensity-modulated radiation therapy. Meanwhile, research on predicting dose distributions in high-precision stereotactic radiotherapy treatments has remained relatively underrepresented. PURPOSE: We aimed to expand the previous studies by developing a DL-based framework for predicting dose distributions for robotic, stereotactic prostate cancer radiotherapy. METHODS: We harnessed a U-Net-based convolutional neural network for predicting clinically achievable dose distributions based on CT images, delineated structures, and distance information from the planning target volume. A dataset of 462 patients treated with CyberKnife (Accuray Inc.) utilizing an Iris collimator was divided into training (70%, n = 323), validation (10%, n = 46), and test (20%, n = 93) sets. RESULTS: In the independent test set, the mean absolute error between the mean doses of predictions and clinical plans was 0.63 Gy for the rectum and 1.04 Gy for the bladder. CONCLUSIONS: The proposed U-Net-based model demonstrated the ability to learn and reproduce characteristic dose distributions in CyberKnife prostate cancer radiotherapy. The model may provide patient-specific dose estimates for setting initial planning objectives to assist in automating treatment planning and improving inter-planner consistency.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- A U-Net-based convolutional neural network framework is developed for predicting dose distributions in CyberKnife prostate cancer radiotherapy.
- The model achieved a mean absolute error of 0.63 Gy for the rectum and 1.04 Gy for the bladder in the independent test set.
- The proposed model may provide patient-specific dose estimates for setting initial planning objectives to assist in automating treatment planning.
Readers' thoughts
No reader thoughts yet.
Related papers
- A cascade deep learning network for simultaneous prediction of dose and linear energy transfer in proton therapy of prostate cancer.Physics in medicine and biology · 2026
- From Predicted Dose to Computationally Verified Plan: An End-to-End Deep Learning and Monte Carlo Pipeline for Automated VMAT Glioblastoma Radiotherapy.Journal of imaging informatics in medicine · 2026
- RADT-46 Evaluation of brain stereotactic radiosurgery plan quality using a dual-model deep learning framework: a cross-platform analysisNeuro-Oncology · 2026
- End-to-end automated radiotherapy planning using transfer learning to overcome data scarcity.Medical physics · 2026
- A generalizable 3D dose prediction across heterogeneous cohorts: A framework developed for the 2025 AAPM GDP-HMM challenge.Medical physics · 2026
- Practical deep learning solutions for prostate cancer segmentation and implementation in radiotherapy planning.Physical and engineering sciences in medicine · 2026