Pulmonary ventilation images from planning CT images using deep learning on locally-advanced NSCLC patients.
Yoshiyuki Katsuta, Taichi Hoshino, Takaya Yamamoto, Noriyuki Kadoya, Shohei Tanaka, Kazuhiro Arai, Rei Umezawa, Noriyoshi Takahashi,
Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan.
Key points
From the paper's conclusion- We successfully developed a framework that estimates CTVI PCT DNN , and demonstrated its estimation performance in terms of Spearman's correlation coefficient and DSC on locally-advanced NSCLC patients.
Abstract
BACKGROUND: Pulmonary ventilation imaging has become an increasingly important component in thoracic radiotherapy, as it is applied to functional avoidance radiotherapy, where radiation doses are strategically minimized to preserve functional lung regions. PURPOSE: We developed a framework that generates computed tomography ventilation images (CTVI) from planning CT (PCT) images and demonstrated its estimation performance. METHODS: The subjects were a patient cohort consisting of 102 locally-advanced non-small-cell lung cancer (NSCLC) patients who received radiotherapy from 2014 to 2023. The PCT images were acquired while ensuring the absence of baseline drift, frequency variation, amplitude changes, and additive random observation noise using a real-time position management (RPM) system to minimize the introduction of inaccuracies into PCT images. On the day of PCT scan, CTVI based on four-dimensional computed tomography images ( CTVI 4 DCT DIR ) images was also generated using both deformable image registration and the computing methods employed in the VAMPIRE study. RESULTS: The CTVI based on PCT ( CTVI PCT DNN ) estimated by a model trained via hyperparameter optimization of a U-net deep neural network with 5-fold cross-validation was compared with CTVI 4 DCT DIR . In 5-fold cross-validation, the average voxel-wise Spearman's correlation coefficient (rs) ± one standard deviation between CTVI PCT DNN and CTVI 4 DCT DIR was 0.77 ± 0.08. The Dice similarity coefficient (DSC) was computed for three functional regions (high, moderate, and low), each delineated by approximately equal volumes, obtaining DSChigh, DSCmoderate, and DSClow values of 0.68 ± 0.06, 0.51 ± 0.08, and 0.75 ± 0.04, respectively. CONCLUSIONS: We successfully developed a framework that estimates CTVI PCT DNN , and demonstrated its estimation performance in terms of Spearman's correlation coefficient and DSC on locally-advanced NSCLC patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Combining handcrafted radiomics features and deep learning features within different regions of interest in planning CT images for the prediction of symptomatic radiation pneumonitis in locally advanced non-small cell lung cancer.Radiation oncology (London, England) · 2026
- Semi-supervised motion and anatomy dual aware fusion network for lung 4D CT ventilation imaging.Artificial intelligence in medicine · 2026
- Functional lung avoidance planning with combined ventilation-perfusion imaging versus individual functional imaging in lung cancer radiotherapy.Physics and imaging in radiation oncology · 2026
- Deep learning for CT-less attenuation correction synthesis in non-small cell lung cancer: A proof-of-concept evaluated for quantitative and physical characteristics.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026
- Relevance between patients' clinical factors and 4D-CT lung ventilation heterogeneity for evaluating the adoption of functional avoidance thoracic radiotherapy with a large patient database.Frontiers in oncology · 2026
- Cone Beam Computed Tomography-based Lung Function Imaging using Deep Learning for Functional Image-Guided Adaptative Radiation Therapy.International journal of radiation oncology, biology, physics · 2026