Fewer Fractions, Equieffective Plans: An optimization framework based on equieffective dose
Suryakant Kaushik, Jakob \"Od\'en, Albin Fredriksson, Iuliana Toma-Dasu
Key points
From the paper's conclusion- Conclusions: An $EQD_{n_{ref}}$-based framework can generate equieffective hypofractionated plans, making it feasible to reduce fractions without substantially deviating from existing clinical protocols.
Abstract
Background: Non-standard fractionation requires caution before clinical use, and planners often need to manually modify the prescription and dose constraints for non-linear biological effects. Purpose: To develop an extension within a treatment planning system that enables the generation of hypofractionated plans based on equieffective dose, $EQD_{n_{ref}}$, for an alternative fractionation deliverable in $n$ fractions, such that it is equieffective with the reference fractionation for a specified biological endpoint. Methods: A research build of RayStation v2025 was extended to optimize $EQD_{n_{ref}}$ plans. This study used anonymized data from three head and neck patients. $\text{CTV}_p$ and $\text{CTV}_n$ were prescribed 70 Gy and 54 Gy in 35 fractions. Targets, spinal cord, and brainstem were robustly optimized for $\pm3.5$% density and $\pm3.0$ mm setup uncertainties. For each patient, hypofractionated plans were created with 34, 32, 30, and 25 fractions. Sensitivity analysis evaluated the impact of $\alpha/\beta$ uncertainty. Results: All equieffective hypofractionated plans maintained target coverage and met mandatory clinical goals for organs-at-risk (OARs). Compared to standard fractionation, DVH parameters indicated an average $\Delta EQD_{n_{ref}}$ <0.2 Gy for $\text{CTV}_p$ and no difference for $\text{CTV}_n$. For parallel OARs, the median mean-dose difference between hypofractionation (to 30 fractions) and standard fractionation was generally <1% of the prescribed dose. $\alpha/\beta$ uncertainty produced the greatest variation in the 25-fraction regimen, with absolute $\Delta EQD_{n_{ref}}$ up to 0.88 Gy for targets and up to 0.63 Gy for the spinal cord and brainstem. Conclusions: An $EQD_{n_{ref}}$-based framework can generate equieffective hypofractionated plans, making it feasible to reduce fractions without substantially deviating from existing clinical protocols.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Local Voxelwise EQD2, Prescription-Fractionation Normalisation, and Common-Fraction Equivalent Dose: A Theoretical and Computational Comparison.Biomedical physics & engineering express · 2026
- Dose-Range-Dependent Voxel-Based Biological Dose Conversion From Thoracic Ultra-Hypofractionation to Conventional Fractionation: A Pilot Evaluation and Framework for Future Multicenter Studies.Cureus · 2026
- Hypofractionated radiotherapy in head and neck cancer: current evidence and future directions, with a focus on laryngeal cancer.Frontiers in oncology · 2026
- Hypofractionated Radiation Therapy for Localized Prostate Cancer: An ASTRO Clinical Practice Guideline.Practical radiation oncology · 2026
- Hypofractionated Versus Normofractionated Accelerated Radiation Therapy With or Without Cisplatin for Locally Advanced Head and Neck Squamous Cell Carcinoma (HYPNO): A Randomized, Open-Label, Phase 3, Noninferiority TrialInternational Journal of Radiation Oncology*Biology*Physics · 2026
- Dose equivalence calculation in radiotherapy: A Call for Standardization.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026