Can LLM Judges Catch Unsafe Clinical Actions? A Fault-Injection Study
Neda Ghafouri
Key points
From the paper's conclusion- We also find that the benchmark's original grader accepts all 38 trajectories with an intentionally skipped laboratory check, while combining LLM judges with a rule-based checker informed by the full EHR record detects 97% of injected faults.
Abstract
As clinical AI agents begin to interact with electronic health records (EHRs), large language models (LLMs) are increasingly used to evaluate their actions. But how reliably can these judges recognize clinically dangerous mistakes, especially when an agent appears to have completed its task successfully? We investigate this question using MedAgentBench by introducing controlled clinical errors into verified agent trajectories. The experiments include 416 faulty trajectories, eight error categories, and six open-weight LLM judges. By comparing each faulty trajectory with its correct counterpart, we measure whether judges genuinely recognize errors rather than simply flagging more actions as unsafe. The findings show that access to clinical evidence significantly improves judge reliability. When shown only the final answer, judges cannot distinguish errors that leave it unchanged, while flagging 56% of correct trajectories. With full trajectory information, the ability to distinguish unsafe actions from correct ones reaches a score of 0.75, and providing actual EHR responses improves discrimination by 0.39. Surprisingly, including the agent's reasoning does not improve overall performance and reduces detection of incorrectly reported clinical values by 0.18, which remain the hardest errors to detect. MedGemma performed worse than the general-purpose model and was the only judge to miss potentially dangerous medication overdoses. We also find that the benchmark's original grader accepts all 38 trajectories with an intentionally skipped laboratory check, while combining LLM judges with a rule-based checker informed by the full EHR record detects 97% of injected faults.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Crisis of Ground Truth in Medical AI: Evaluating the Tools Used to Detect LLM HallucinationsInternational Journal for Research in Applied Science and Engineering Technology · 2026
- Medical Fine-Tuning Reshapes, Not Reduces, Patient-Facing AI Risk: A Rubric-Based, LLM-Judge Evaluation FrameworkarXiv · 2026
- Beyond Accuracy: A Critical Review of Evaluation, Clinical Validation, and Safety Frameworks for Agentic AI in MedicineInformation · 2026
- MedToolFault and MedGuard: evaluating and improving clinical agent reliabilityarXiv · 2026
- Same Patient, Different Order: Action-Level Reliability of Clinical LLM Agents Under Repeated RunsarXiv · 2026
- A medically grounded LLM agent-based tool to detect patient safety events in medical records.PLOS digital health · 2026