arXivPreprintOpen accessphysics.med-ph

High-Receiver-Bandwidth MRI Near Metal Implants with Motion-Consistent Rep2Rep Denoising

Iman Khodarahmi, Renqing Luo, Nikola Janju\v{s}evi\'c, Christopher J Burke, Shana G Neumann, Yao Wang, Li Feng

Key points

From the paper's conclusion
  • Conclusion: High-receiver-bandwidth MRI with motion-consistent self-supervised Rep2Rep denoising reduces metal-induced artifact without requiring dedicated high-receiver-bandwidth training data.

Abstract

Purpose: To develop and evaluate a self-supervised denoising approach using motion-consistent Rep2Rep learning to enable high-receiver-bandwidth MRI for reduced metal-induced distortion. Methods: Motion-consistent Rep2Rep generates anatomically consistent training repetitions in the presence of inter-repetition motion by combining two acquired repetitions and splitting the combined k-space along the readout direction. The model was trained on 134 clinical low-receiver-bandwidth (300 Hz/pixel) MRI datasets and applied to 59 high-receiver-bandwidth (1028 Hz/pixel) MRI datasets. Three musculoskeletal radiologists independently scored low- and high-receiver-bandwidth images (before and after denoising) in a blinded manner for metal artifact reduction, image sharpness, perceived SNR, and overall image quality. A separate blinded reader preference evaluation was performed to compare motion-consistent Rep2Rep with standard Rep2Rep. Results: High-receiver-bandwidth MRI significantly reduced metal-induced artifact, while motion-consistent Rep2Rep improved perceived SNR and overall image quality. Compared to clinical low-receiver-bandwidth MRI, denoised high-receiver-bandwidth MRI achieved significantly higher metal artifact reduction scores (sagittal: 3.69 vs 3.01; axial: 3.83 vs 3.05; both P<0.0001) and comparable overall image quality scores (sagittal: 4.03 vs 3.98, P = 0.5391; axial: 3.95 vs 3.87, P=0.1266). The high-receiver-bandwidth axial protocol also reduced acquisition time by 47%. Motion-consistent Rep2Rep better preserved fine anatomical details than standard Rep2Rep. Conclusion: High-receiver-bandwidth MRI with motion-consistent self-supervised Rep2Rep denoising reduces metal-induced artifact without requiring dedicated high-receiver-bandwidth training data. This offers a practical approach for MRI near metal implants, such as postoperative cervical spine imaging.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

High-Receiver-Bandwidth MRI Near Metal Implants with Motion-Consistent Rep2Rep Denoising — Science Skim