High-Receiver-Bandwidth MRI Near Metal Implants with Motion-Consistent Rep2Rep Denoising
Iman Khodarahmi, Renqing Luo, Nikola Janju\v{s}evi\'c, Christopher J Burke, Shana G Neumann, Yao Wang, Li Feng
Key points
From the paper's conclusion- Conclusion: High-receiver-bandwidth MRI with motion-consistent self-supervised Rep2Rep denoising reduces metal-induced artifact without requiring dedicated high-receiver-bandwidth training data.
Abstract
Purpose: To develop and evaluate a self-supervised denoising approach using motion-consistent Rep2Rep learning to enable high-receiver-bandwidth MRI for reduced metal-induced distortion. Methods: Motion-consistent Rep2Rep generates anatomically consistent training repetitions in the presence of inter-repetition motion by combining two acquired repetitions and splitting the combined k-space along the readout direction. The model was trained on 134 clinical low-receiver-bandwidth (300 Hz/pixel) MRI datasets and applied to 59 high-receiver-bandwidth (1028 Hz/pixel) MRI datasets. Three musculoskeletal radiologists independently scored low- and high-receiver-bandwidth images (before and after denoising) in a blinded manner for metal artifact reduction, image sharpness, perceived SNR, and overall image quality. A separate blinded reader preference evaluation was performed to compare motion-consistent Rep2Rep with standard Rep2Rep. Results: High-receiver-bandwidth MRI significantly reduced metal-induced artifact, while motion-consistent Rep2Rep improved perceived SNR and overall image quality. Compared to clinical low-receiver-bandwidth MRI, denoised high-receiver-bandwidth MRI achieved significantly higher metal artifact reduction scores (sagittal: 3.69 vs 3.01; axial: 3.83 vs 3.05; both P<0.0001) and comparable overall image quality scores (sagittal: 4.03 vs 3.98, P = 0.5391; axial: 3.95 vs 3.87, P=0.1266). The high-receiver-bandwidth axial protocol also reduced acquisition time by 47%. Motion-consistent Rep2Rep better preserved fine anatomical details than standard Rep2Rep. Conclusion: High-receiver-bandwidth MRI with motion-consistent self-supervised Rep2Rep denoising reduces metal-induced artifact without requiring dedicated high-receiver-bandwidth training data. This offers a practical approach for MRI near metal implants, such as postoperative cervical spine imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance of a GPU- and time-efficient pseudo-3D network for magnetic resonance image super-resolution and motion artifact reductionScientific Reports · 2026
- Unsupervised high-resolution 3D MRI motion correction via physics-informed implicit neural representations.Medical image analysis · 2026
- Self-supervised reconstruction framework via motion- and physics-informed learning for four-dimensional magnetic resonance fingerprinting.Medical image analysis · 2026
- Learning Dynamic Affinity Diffusion for Multi-Contrast MRI Super-Resolution via Implicit Neural Representations.NeuroImage · 2026
- PGDM-MRSRGAN: Physics-Guided Degradation Model with an SRGAN Framework for Magnetic Resonance Image Super-Resolution: Applications in Low-Field MRI.ArXiv · 2026
- Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction.IEEE transactions on medical imaging · 2026