Ion Backflow Suppression and Absorption Dynamics in Cascaded GEM Structures
Md Kaosor Ali Mondal, Shakir Eqbal, Sachin Rana, Poojan Angiras, A. Sarkar
Key points
From the paper's conclusion- These findings establish that ion suppression in cascaded GEM structures is governed not only by the number of foils but primarily by the local ion-collection properties of each foil, and that single-conical holes represent a promising route to improved performance in high-rate detector applications.
Abstract
Ion backflow (IBF) is a persistent challenge in Gas Electron Multiplier (GEM) detectors: positive ions drifting back into the sensitive volume distort the drift field and degrade both spatial and energy resolution. We investigate the ion-absorption characteristics of single- to quintuple-GEM detectors using ANSYS and Garfield$^{++}$ for an Ar/CO$_2$ (70:30) gas mixture. A layer-resolved formalism is developed that distinguishes conditional foil-level absorption from a detector-level absorption metric that correctly weights ion production at every amplification stage. For the conventional biconical geometry, cascading foils improves the overall ion-absorption fraction only moderately, from 47.83\% for a single GEM to 59.06\% for a quintuple GEM. Replacing the biconical holes with a single-conical profile raises the absorption fraction to 75\%-87\% across the same range of multiplicities and reduces the IBF/Gain ratio by a factor of two to three an improvement that exceeds what is gained by adding four additional biconical foils. As a secondary test under more realistic conditions, the second transfer-gap length of a triple-GEM detector is varied from 1.2 to 3.5~mm. The gain shows a non-monotonic dependence with a maximum near 2.0-2.5~mm, while the IBF/Gain ratio decreases monotonically with increasing gap length; the single-conical geometry retains its factor-of-two advantage throughout. These findings establish that ion suppression in cascaded GEM structures is governed not only by the number of foils but primarily by the local ion-collection properties of each foil, and that single-conical holes represent a promising route to improved performance in high-rate detector applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Negative ions as charge carriers in gaseous detectors: Results in Xe, SF6 and Xe-SF6 mixturesNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2026
- Performance and Stability Studies of GEM Detectors for High Energy Physics ApplicationsarXiv · 2026
- Investigation on effects of injection hole geometry on mixing characteristics of powder fuel in cavity combustor under supersonic flowJournal of Physics: Conference Series · 2026
- Efficiency measurements of GEM GE1/1 chambers in the upgraded CMS Endcap Muon System using 2023 collision data at √( s ) = 13.6 TeVJournal of Instrumentation · 2026
- Multithreaded Garfield++ simulation of THGEM charging-up effectsJournal of Instrumentation · 2026
- Modeling the light response of an optically readout GEM based TPC for the CYGNO experimentThe European Physical Journal C · 2026