  • These findings establish that ion suppression in cascaded GEM structures is governed not only by the number of foils but primarily by the local ion-collection properties of each foil, and that single-conical holes represent a promising route to improved performance in high-rate detector applications.

Abstract

Ion backflow (IBF) is a persistent challenge in Gas Electron Multiplier (GEM) detectors: positive ions drifting back into the sensitive volume distort the drift field and degrade both spatial and energy resolution. We investigate the ion-absorption characteristics of single- to quintuple-GEM detectors using ANSYS and Garfield$^{++}$ for an Ar/CO$_2$ (70:30) gas mixture. A layer-resolved formalism is developed that distinguishes conditional foil-level absorption from a detector-level absorption metric that correctly weights ion production at every amplification stage. For the conventional biconical geometry, cascading foils improves the overall ion-absorption fraction only moderately, from 47.83\% for a single GEM to 59.06\% for a quintuple GEM. Replacing the biconical holes with a single-conical profile raises the absorption fraction to 75\%-87\% across the same range of multiplicities and reduces the IBF/Gain ratio by a factor of two to three an improvement that exceeds what is gained by adding four additional biconical foils. As a secondary test under more realistic conditions, the second transfer-gap length of a triple-GEM detector is varied from 1.2 to 3.5~mm. The gain shows a non-monotonic dependence with a maximum near 2.0-2.5~mm, while the IBF/Gain ratio decreases monotonically with increasing gap length; the single-conical geometry retains its factor-of-two advantage throughout. These findings establish that ion suppression in cascaded GEM structures is governed not only by the number of foils but primarily by the local ion-collection properties of each foil, and that single-conical holes represent a promising route to improved performance in high-rate detector applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Ion Backflow Suppression and Absorption Dynamics in Cascaded GEM Structures — Science Skim