arXivPreprintOpen accesscs.LG

PhyMind: Physics-Informed Masked Autoencoding for EEG Foundation Models

A Adith

Key points

From the paper's conclusion
  • PhyMind keeps a standard masked transformer encoder, but its decoder must explain the masked signal through 68 cortical regions, each driven by damped stochastic oscillators and an aperiodic Ornstein-Uhlenbeck process, projected to the recording's own montage by a fixed boundary-element lead field evaluated per derivation.

Abstract

EEG foundation models are pre-trained almost exclusively with masked reconstruction through a free-form decoder, sometimes with hand-crafted spectral targets added, as in MANAS-2. We study what happens when that decoder is replaced by a generative forward model of EEG. PhyMind keeps a standard masked transformer encoder, but its decoder must explain the masked signal through 68 cortical regions, each driven by damped stochastic oscillators and an aperiodic Ornstein-Uhlenbeck process, projected to the recording's own montage by a fixed boundary-element lead field evaluated per derivation. Training combines masked reconstruction with a Whittle spectral likelihood, an oscillator-dynamics residual, a minimum-norm source prior and a penalised neural residual. In a controlled comparison (same encoder, data, steps and seed), the physics decoder produces encoder tokens whose spectral content is far more linearly decodable than with a masked-autoencoder decoder or with the MANAS-2 objective: mean R^2 on a token-level spectral probe with amplitude-normalised targets is 0.67/0.77/0.77 on three datasets, against 0.24/0.50/0.50 (MAE) and 0.48/0.67/0.66 (MANAS-2 objective), approaching the released 92.8M-parameter MANAS-2 (0.71/0.81/0.80). Downstream gains in the controlled setting are small (four-task mean balanced accuracy 56.6 vs. 53.8 for MAE frozen, 63.8 vs. 62.7 fine-tuned). Region-level features from the physics decoder raise frozen four-class motor-imagery accuracy by 7-14 points, so a 7.2M-parameter model pre-trained on 3k hours of open EEG is comparable to the released MANAS-2 with frozen features (63.0 vs. 61.6). After full fine-tuning, MANAS-2 remains better (66.8 vs. 65.4 for our best model). The inferred sources do not reproduce the lateralisation that a classical inverse solution finds in motor imagery, so we do not claim anatomical interpretability. Code and weights are released.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

PhyMind: Physics-Informed Masked Autoencoding for EEG Foundation Models — Science Skim