eSPG: The Unreasonable Effectiveness of Event Speckle Plethysmography
Aniket Dashpute, Anirudh Bindiganavale Harish, Bhargav Ghanekar, Alankar Kotwal, Andrew Negrut, Syna Gupta, Pablo A. Valdes, Ashok Veeraraghavan
Key points
From the paper's conclusion- Here we introduce event speckle plethysmography (eSPG), which illuminates a body part with a low-power (0.5-5 mW) laser and captures the resulting dynamic speckle pattern using an event camera.
Abstract
Non-contact measurement of vital signs such as heart rate (HR) is valuable for patient monitoring and rescue operations. However, existing methods struggle with ambient illumination and motion, and have been demonstrated only at distances of tens of meters. Here we introduce event speckle plethysmography (eSPG), which illuminates a body part with a low-power (0.5-5 mW) laser and captures the resulting dynamic speckle pattern using an event camera. Event cameras, with their high dynamic range, temporal resolution, and sensitivity to intensity changes, are well-suited to capturing rapid speckle fluctuations that encode the physiological signal, even under challenging illumination and imaging conditions. We demonstrate HR estimation at 1 km with a mean absolute error of 5 beats per minute, and 90% of estimates satisfy an AAMI-defined HR estimation criterion. This distance exceeds previous remote plethysmography demonstrations by an order of magnitude and previous speckle plethysmography demonstrations by over three orders of magnitude. We also study and characterize robustness to motion and ambient illumination. Our theoretical analysis and experimental results demonstrate that resolving dynamic speckle fluctuations enables accurate heart rate estimation even at kilometer-scale distances, establishing a new direction toward robust, non-contact physiological monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Contactless camera-based estimation of heart rate and variability from short facial video using remote photoplethysmography, remote ballistocardiography, and quality-aware selectionEuropean Heart Journal · 2026
- The reliability of remote photoplethysmography under low illumination and elevated heart ratesnpj Digital Medicine · 2025
- A Novel Cluster-Based Approach for PPG Signal Preprocessing: Motion Artifact Filtering and Ambient Light Correction.Sensors (Basel, Switzerland) · 2026
- Contactless Vital Sign Monitoring in Emergency Settings: A Factorial Study of Camera Position and Motion Using rPPGAlgorithms · 2026
- Missed isochromatic cardiac pulsation in remote photoplethysmography: detection, impact, and removalBiomedical Optics Express · 2026
- MS-rPPG: Multi-spectral State Space Model for Remote Photoplethysmography in Driver Monitoring SystemsarXiv · 2026