Single-Pulse Dosimetry for Ultra-High-Dose-Rate X-Ray Pulses Based on Radiation-Induced Acoustic Signals
Qihang Han, Ke Chen, Chenghao Hua, Haoran Chen, Lili Ding, Changhui Li, Xiaoping Ouyang, Chenhui Wang,
Key points
From the paper's conclusion- These results demonstrate the feasibility of single-pulse acoustic dosimetry under the tested conditions.
Abstract
Real-time dosimetry of ultra-high-dose-rate (UHDR) pulsed X-rays remains a major challenge. This proof-of-principle study investigates a dosimetry method for UHDR pulsed X-rays based on radiation-induced acoustic (RA) signals from a thin metal foil. The foil combines efficient X-ray absorption and acoustic resonance, converting deposited dose into acoustic signals with discrete resonant frequencies. Single-pulse measurements were performed at six dose levels spanning approximately 1--40 mGy(Si), with one pulse recorded at each level and instantaneous dose rates reaching the order of 10^6 Gy/s at the highest dose settings. The peak-to-peak amplified transducer-output voltage exhibited a linear relationship with the reference dose measured by thermoluminescent dosimeters (TLDs). These results demonstrate the feasibility of single-pulse acoustic dosimetry under the tested conditions. Furthermore, we establish analytical solutions for radiation-induced acoustic signals in a one-dimensional layered medium in both the time and frequency domains, providing a theoretical basis for signal interpretation and detector optimization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A scintillator-based approach to spatial and temporal dosimetry in UHDR electron irradiationJournal of Physics: Conference Series · 2026
- X-ray FLASH: Technologies, evidence and challenges to translation.The British journal of radiology · 2026
- Toward quantitative reconstruction of delivered dose in a 3D digital water phantom for electron FLASH-RT via annular-array electron-induced acoustic imaging.Physics in medicine and biology · 2026
- Ultra-high-dose-rate pulsed irradiation and the conditional FLASH effect: dosimetry, multiscale biology, and clinical translation.Frontiers in oncology · 2026
- Comparative analysis of the responses of EBT-XD and EBT4 films to ultra-high dose rate proton beamsRadiation Physics and Chemistry · 2025
- Pulse-resolved spatial dosimetry of ultra-high dose rate electron FLASH beams using optical imaging.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026