arXivPreprintOpen accessphysics.ins-det

The Simons Observatory: A Novel Design for Heat Strap at Sub-Kelvin Temperatures

John Orlowski-Scherer, Oorie Desai, Daniel Lee, Nicholas Galitzki, Alex Manduca, Mark Devlin, Dominic Horne, Henry Nachman,

Key points

From the paper's conclusion
  • We present a novel process for the fabrication of copper heat straps and a measurement of their thermal performance at sub-Kelvin temperatures.

Abstract

We present a novel process for the fabrication of copper heat straps and a measurement of their thermal performance at sub-Kelvin temperatures. The conductance of the heat straps is consistent with the bulk conductivity of annealed copper over the range 60 mK to 1 K. We find no evidence for deviation from a linear dependence of conductivity with temperature over the explored range, indicating that the contact resistance at the strap ends is sub-dominant. Heat straps developed and validated through the described process have been deployed in both the Large Aperture Telescope Receiver and a Small Aperture Telescope of the Simons Observatory and have met thermal requirements.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers