Feasibility of Multifrequency Neural Network-Based Wave Inversion in Ultrasound Time-Harmonic Elastography
H\'elo\"ise Bustin, Tom Meyer, Paul Spiesecke, Jakob Jordan, Anja Hennemuth, Ingolf Sack
Key points
From the paper's conclusion- We tested our approach on THE acquired phantom data from the algorithms for mapping elastic modulus Challenge, as well as on in vivo liver THE in 4 healthy volunteers and 14 patients with focal liver lesions, including benign focal nodular hyperplasia, and malignant hepatocellular carcinoma and adenocarcinoma.
Abstract
Ultrasound time-harmonic elastography (THE) is a non-invasive imaging technique that measures soft-tissue stiffness. Relying on the same principle of time-harmonic shear wave excitation as established magnetic resonance elastography (MRE), THE offers full field-of-view stiffness mapping at short acquisition times and sub-second temporal resolution across organs. However, reconstruction of shear wave speed maps from acquired tissue wavefields remains challenging due to speckle noise and sparse spatial coverage of the lateral component. Deep learning methods have shown promising results for image reconstruction in transient-based ultrasound elastography modalities but remain unexplored in THE. In MRE, MF-ElastoNet, a 2D multifrequency neural network-based wave reconstruction method trained on synthetic physics-based wave data, has shown high generalizability across dynamic ranges and resolutions. We investigated the potential of a multifrequency neural network-based wave inversion for THE, by performing a first feasibility analysis. To this end, we adapted the processing pipeline of MF-ElastoNet from MRE to THE. We tested our approach on THE acquired phantom data from the algorithms for mapping elastic modulus Challenge, as well as on in vivo liver THE in 4 healthy volunteers and 14 patients with focal liver lesions, including benign focal nodular hyperplasia, and malignant hepatocellular carcinoma and adenocarcinoma. MF-ElastoNet was successfully adapted to THE with in vivo liver testing. Compared with k-MDEV, the state-of-the-art wave inversion method for THE, Bland-Altman analysis showed a mean bias of -0.02 m/s (95% limits of agreement: -0.36 to 0.33 m/s).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multifrequency neural network-based wave inversion in MR elastography with uncertainty quantification.Medical image analysis · 2026
- Deep-DoPIo: Deep Learning for Shear Elasticity Prediction in Double-Profile Intersection Ultrasound.IEEE transactions on ultrasonics · 2026
- Physics-Informed Deep Learning for Shear Wave Speed Estimation in MR ElastographyarXiv · 2026
- Estimation of shear wave 3D velocity fields from echocardiographic time-of-flight data using physics-informed neural networks.IEEE transactions on ultrasonics · 2026
- Multitask Learning Framework for Elasticity and Viscosity Image Reconstruction in Ultrasound Viscoelastography.IEEE transactions on ultrasonics · 2026
- Accelerated MR Elastography Using Learned Neural Network Representation.Magnetic resonance in medicine · 2026