International journal of oral implantology (Berlin, Germany)

Association of probing depth and crestal bone loss at implants: A long-term 5- to 20-year cohort study in periodontally stable patients.

Rodopi Emfietzoglou, Martin Mogk, Reiner Mengel

Observational · n=71

Key points

From the paper's conclusion
  • Moderate crestal bone loss occurred during loading without association with peri-implant probing depth. All other follow-up time points showed no significant differences between surface types; only at 15 years did machined implants exhibit moderately increased bone loss. Overall, the cohort demonstrated stable long-term outcomes.

Abstract

PURPOSE: The aim of this long-term cohort study in periodontally stable patients with dental implants was to investigate the association between probing depth and peri-implant bone loss and compare outcomes between implants with machined versus rough surfaces. MATERIALS AND METHODS: A total of 268 implants were inserted in 71 patients and restored with fixed crowns or partial dentures. All patients participated in a supportive periodontal therapy programme with recall intervals of 3 to 6 months over a follow-up period ranging from 5 to 20 years. Clinical parameters were recorded at each follow-up visit. Standardised intraoral radiographs were taken at baseline (immediately after superstructure insertion) and at 1, 3, 5, 10, 15 and 20 years thereafter. RESULTS: Mean crestal bone loss between implant placement and superstructure insertion (baseline) was 0.99 ± 0.75 mm. During the loading phase, peri-implant bone loss increased to 1.60 ± 0.90 mm at the 20-year follow-up. Mixed-effects analysis showed no differences in bone loss between surface types except at the 15-year follow-up, when machined surfaces exhibited moderately greater bone loss (P = 0.026). The majority of implant sites displayed shallow probing depths, with 87.4% (4,181 sites) 4 mm, 12.6% (602 sites) ≥ 4 mm and 0.4% (19 sites) ≥ 6 mm. Probing depth did not differ between groups, except at 5 years, when machined-surface implants showed higher probing depths than rough-surface implants (P = 0.026). A weak association between probing depth and bone loss was observed only at the 2- to 3-year follow-up period (P = 0.05). CONCLUSION: Moderate crestal bone loss occurred during loading without association with peri-implant probing depth. All other follow-up time points showed no significant differences between surface types; only at 15 years did machined implants exhibit moderately increased bone loss. Overall, the cohort demonstrated stable long-term outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers