Compact and Decodable Electrocardiogram Text for Large Language Models
Elif Dorukba\c{s}{\i}, \.Ilker T\"urker
Key points
From the paper's conclusion- The diagnostic content of a compact text can therefore be preserved, while the language model's ability to read the text is yet another matter.
Abstract
When a twelve-lead electrocardiogram is written as text for a large language model, the number of tokens has to be balanced against the information lost through compression. This paper presents a deterministic encoding that writes eight independent leads as amplitude letters and exact time gaps and recovers the remaining four limb leads algebraically. The key points are selected with a cardiac-cycle-dependent tolerance, the amplitudes are parameterized by a 26-letter logarithmic codebook learned from a training set, and a 10-step tolerance schedule keeps all records within a fixed token budget. The encoding was applied to 21,388 records from the public PTB-XL database and evaluated using an exact decode-and-re-encode round trip, waveform reconstruction error, and a paired comparison of convolutional classifiers trained with 5 different seeds on signals from the original and decoded databases. All records were contained in 4,080 tokens (average: 2,866 tokens, 64.3% fewer than a per-sample transcription), and all stored lead strings were exactly reproduced. The average correlation between the decoded and reference signals was 0.982. The macro-averaged area under the receiver operating characteristic curve was 0.9167 for the reference signals and 0.9157 for the decoded signals (paired difference -0.0010; 95% patient-level bootstrap interval, -0.0028 to 0.0007), within the pre-specified non-inferiority margin of -0.010; this is not a confirmatory result, because the test fold had been used during encoder development. The diagnostic content of a compact text can therefore be preserved, while the language model's ability to read the text is yet another matter.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- LEAP-LLM: Preserving lead-time structure for question-conditioned ECG interpretationarXiv · 2026
- Multimodal large language models demonstrate consistently low accuracy for 12-lead electrocardiogram interpretation: a 599-case benchmark studyEuropean Heart Journal · 2026
- The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation LearningarXiv · 2026
- ECGJev: Question-Conditioned Option Scoring for 12-Lead ECG InterpretationarXiv · 2026
- ECGQuest: Benchmarking and Fine-Tuning Language Models for ElectrocardiographyarXiv · 2026
- Artificial intelligence-based automated interpretation of images of electrocardiograms: development and multinational validation of ECG-GPTEuropean Heart Journal - Digital Health · 2026