Stop Early, Stay Simple: Evidence Acquisition for Power System Fault and Attack Diagnosis
S M Zia Ur Rashid, Sazidul Islam Hira, Rupesh Sah, Suman Rath
Key points
From the paper's conclusion- We ask when a learned policy for choosing that evidence is worth its added complexity.
Abstract
Diagnostic models for cyber-physical power systems usually inspect every telemetry source for every event, although some events are clear from one source and others need several. We ask when a learned policy for choosing that evidence is worth its added complexity. To answer this, we present ActiGrid, a benchmark framework for active evidence acquisition that pairs a classifier trained to tolerate missing modalities with a Double Deep Q-Network (DQN), which either requests another source or stops and diagnoses but never operates grid actuators. On the public TU Delft digital substation and MSU/ORNL power system attack benchmarks, we compare the DQN with fixed subsets and orders, calibrated entropy stopping, a greedy value of information rule, and tree ensembles trained per subset. The learned policy does adapt to what it observes, yet it is statistically indistinguishable from entropy stopping on TU Delft and Pareto dominated by simple controls on MSU/ORNL, while compact subset classifiers outperform it while reading fewer sources on both benchmarks. Entropy stopping run over those subset classifiers reaches the highest mean Macro-F1 on TU Delft (0.928 while reading 57% of the sources) but brings no saving over a static three source subset on MSU/ORNL, where no method exceeds 0.45 Macro-F1. Selective acquisition can pay off, but on these benchmarks it does not need a learned policy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Identifiability-Aware, Cost-Aware Triage of Physical Faults and Measurement-Integrity Anomalies in Energy Cyber-Physical Systems.Sensors (Basel, Switzerland) · 2026
- Agreement Is Not Assurance: Evidence-Independent Safety Gates for Agentic AI in DER-Rich Distribution GridsarXiv · 2026
- Benchmarking Physics-Informed, Cost-Sensitive Detectors of False Data Injection Attacks Against AC Power System State EstimationEnergies · 2026
- HESP: Separating What to Probe from When to Stop in Local LLM Alert-Triage AgentsarXiv · 2026
- When Learned IDS Model Selection Collapses to a Static Choice: A Measurement Study at the EdgearXiv · 2026
- Interpretable Cyber-Physical Attack Detection in Smart Grids: A Leakage-Controlled Multi-Testbed Evaluation of Fusion, Robustness, and Observability LimitsarXiv · 2026