How many events does entanglement-based positronium imaging need? Information limits of Compton polarimetry with CZT detectors
Haitao Zhou, Ruonan Wang, Jianyong Hu, Zhifang Wu, Sijin Li
Key points
From the paper's conclusion- We parameterise the measurement by the linear-polarisation correlation coefficient $\kappa$ ($\kappa=1$ maximally entangled, $1/2$ separable), derive the classical Fisher information of double-Compton events and compare it with the quantum Fisher information, relate $\kappa$ to the annihilation channels of positronium in tissue, and simulate pixelated CdZnTe (CZT) rings.
Abstract
The degree of polarisation correlation of the two annihilation photons, measured by Compton polarimetry, has been proposed as a PET biomarker of tissue microstructure, but the statistics it requires have not been quantified. We parameterise the measurement by the linear-polarisation correlation coefficient $\kappa$ ($\kappa=1$ maximally entangled, $1/2$ separable), derive the classical Fisher information of double-Compton events and compare it with the quantum Fisher information, relate $\kappa$ to the annihilation channels of positronium in tissue, and simulate pixelated CdZnTe (CZT) rings. The model is checked against three published measurements and an independent GATE/Geant4 simulation. A double-Compton event carries at most 0.12-0.14 units of Fisher information about $\kappa$ and 0.015 on average, 0.1-0.6% of the quantum limit. Event-wise maximum likelihood reaches the Cramer-Rao bound, whereas the conventional ratio R needs 1.2-2.3 times more events. The observed coefficient is $\kappa_{obs}=1-\alpha(1-\kappa_{pick})$, with a pick-off share $\alpha$ of 0.13-0.29 in tissue; it is sensitive to lipid fraction but not to oxygen, and carries no tissue information if pick-off photons are maximally entangled. Published porous-polymer data imply $\kappa_{pick}$ = 0.34-0.58. In a 15-mm CZT module, ordering ambiguity, position errors and electron transport roughly halve the information per event, and sequence reconstruction of multi-site events recovers this loss. With $^{18}$F and an eight-module ring, $\kappa$ can be measured to $\pm0.01$ in a 10-mm tumour, but separating tissues by $\kappa$ alone requires 6-74 times more decays than are available.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Witnessing Polarization Entanglement of Annihilation Photons via Compton ScatteringarXiv · 2026
- Probing arbitrary polarized photon pairs undergoing double Compton scatterings by a dedicated MC simulator validated with experimental dataThe European Physical Journal C · 2025
- Recent Progress and Perspectives in Positronium Imaging with the 3γ/2γ RatioCondensed Matter · 2026
- Integration of Spectral CT with PET and SPECT: Bringing Tissue Composition Information to Molecular Imaging.ArXiv · 2026
- Photon-counting CT angiography in a multi-trauma patient with bilateral pulmonary embolism: combined vascular mapping and quantitative iodine-density assessment prior to scalp reconstruction: case report.Frontiers in medicine · 2026
- Task-based detectability and angular-sampling bounds on spatial resolution in cone-beam micro-CT: a closed-form scan-design analysis.Medical physics · 2026