Quantitative measurement of microwave power at millikelvin temperatures: Comparison between dispersively and directly coupled superconducting qubits
Asen L. Georgiev, Christoph Kissling, Fabian Kaap, Victor Gaydamachenko, Lukas Gr\"unhaupt, Mark Bieler
Key points
From the paper's conclusion- Here, we apply this concept to superconducting qubits and use them for quantitative measurement of microwave power at millikelvin temperatures.
Abstract
The Rabi frequency of a two-level system is directly proportional to the electric field amplitude being incident on this system. Taking advantage of this relationship, it is possible to use two-level systems as quantitative sensors of electric fields. Here, we apply this concept to superconducting qubits and use them for quantitative measurement of microwave power at millikelvin temperatures. Our superconducting circuit design includes three transmon qubits directly coupled to the central microwave feedline and three transmon qubits coupled dispersively via readout resonators to the feedline. We compare both coupling schemes to assess their reliability for microwave power sensing. Further, we describe the modeling behind each power-sensing method, including an uncertainty estimation based upon repeated measurements. By combining dispersively coupled and directly coupled qubits on the same device, we are able to explore different power ranges: from $-155\;$dBm to $-130\;$dBm for the directly coupled qubits and from $-95\;$dBm to $-55\;$dBm for the dispersively coupled qubits. When determining the microwave-line attenuation for a frequency of $6.0\;$GHz from room temperature to the millikelvin stage of the cryostat, we obtain best estimates and uncertainties for the directly coupled transmons of $(74.7\pm 0.2) \;$dB and for the dispersively coupled transmons of $(75.4\pm 6.8) \;$dB. The larger uncertainty of the dispersively coupled qubit measurements indicates that these qubits are less reliable for power sensing than the directly coupled qubits, most likely, due to the additional coupling resonator, whose transfer function is difficult to estimate accurately. Our results constitute the first step towards validation of qubit power sensing in dilution fridges, leading towards traceability for cryogenic microwave measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Calibration-free quantum thermometry with strain-swept two-level defectsarXiv · 2026
- Millimeter Wave Readout of a Superconducting Qubit.Physical review letters · 2026
- From Macroscopic Quantum Tunneling to Circuit QED: Coherence and Dissipation in 3D Transmon QubitsBrazilian Journal of Physics · 2026
- Scanning-Probe Quantum Sensing of a Microwave and Static Magnetic Field Response of an On-Chip Superconducting Resonator.Nano letters · 2026
- Local Broadband Gigahertz Spectroscopy via SQUID-on-Tip DC ReadoutarXiv · 2026
- Calibrating magnetic flux control in superconducting circuits by compensating distortions on timescales from nanoseconds up to tens of microsecondsPhysical Review Research · 2025