Gas expansion in global models of nanosecond pulsed discharges: a reduced gas-dynamic model coupled to plasma kinetics
Konstantinos Kourtzanidis, Rention Pasolari
Key points
From the paper's conclusion- We couple it with our in-house global plasma-kinetics solver (SoPlasma-0D), whose energy partition after the pulse agrees well with that derived from measurements and with an independent calculation.
Abstract
Global (zero-dimensional) kinetic models of nanosecond pulsed discharges describe the expansion of the heated gas channel (kernel) with simplified gas-dynamic closures. We show that these closures can lead to errors of tens of percent in the calculated gas density, temperature and species densities, especially in the first microseconds after every pulse. Here, we propose a fast, reduced gas-dynamic model of Lagrangian shells, closed by an approximate cylindrical acoustic radiation condition, with no fitted physical coefficient. The reduced model reproduces the axis density obtained by verified one- dimensional compressible computational fluid dynamics (CFD) simulations within 2.4% for smooth deposition profiles and axis pressures up to six times ambient, typically a thousand times faster than CFD. We couple it with our in-house global plasma-kinetics solver (SoPlasma-0D), whose energy partition after the pulse agrees well with that derived from measurements and with an independent calculation. Two microseconds after a single pulse in air, and compared with the proposed coupled model, the existing closures overestimate the axis density by up to a factor of 2.8, the atomic oxygen density by up to 2.7 and the temperature by up to 680 K. For repetitive pulses 200 or 430 ns apart, of equal energy per unit volume, no existing closure follows the coupled model at both intervals, in the gas density met by each later pulse and in the energy per molecule deposited by late pulses, which sets how strongly they dissociate and heat the gas. The proposed reduced model should therefore be used to describe the gas evolution during the expansion phase after every nanosecond pulse, and for repetitive pulses above about 100 kHz in kernels of radius up to about a millimetre.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Modeling Time-Resolved Compressible Effects in Low-Mach Solvers: Numerical Simulations of a Nanosecond DischargeJournal of Physics D: Applied Physics · 2026
- Research on kinetic simulation of methane–air nanosecond pulse discharge plasma under wide operating conditionsPlasma Science and Technology · 2026
- Streamer-to-spark transition in interacting multi-channel pulsed discharges with gasdynamic effectsPhysics of Fluids · 2026
- Plasma morphology under nanosecond repetitively pulsed discharges with air cross-flow: A simulation studyarXiv · 2026
- Beyond electron impact: Dissociation driven by molecular collisions in CO2 nanosecond pulsed plasmasJournal of CO2 Utilization · 2026
- Modeling of Chemically Reactive Gas Flows for Multi-Scale ProblemsarXiv · 2026