Flexible Multi-Stack Super-Resolution of Clinical Brain MRI Using Hetero-Orientation Variational Encoding: Expert Reader Evaluation in a Nigerian Cohort
Kabir Hamzah Muhammad, Lorena Garcia-Foncillas Macias, Soumya Snigdha Kundu, Emily Guilhem, Jon Cleary, Amal Saleh Nour, Yodit Abraham Yaynishet, Chinasa Kalaiwo,
Key points
From the paper's conclusion- We introduce MS-HVED, a sequence-agnostic framework for flexible multi-stack brain MRI super-resolution.
Abstract
High-resolution brain MRI is important for neuroradiological assessment, yet routine clinical protocols often rely on fast, anisotropic 2D acquisitions, particularly in resource-constrained settings. These acquisitions may differ in orientation, alignment and anatomical coverage, resulting in partially overlapping image stacks. Existing learning-based super-resolution methods typically rely on single, under-constrained inputs or fixed multi-stack configurations with idealised acquisition geometry. We introduce MS-HVED, a sequence-agnostic framework for flexible multi-stack brain MRI super-resolution. Available axial, coronal and sagittal stacks are independently encoded into multi-scale Gaussian posteriors and fused using a field-of-view-aware Product-of-Gaussians formulation that limits contributions from unsupported regions. Physics-informed domain randomisation simulates heterogeneous clinical acquisition conditions, including obliqueness, partial coverage and imaging artefacts. MS-HVED achieved competitive or superior reconstruction fidelity across synthetic benchmarks and improved downstream tissue segmentation relative to low-resolution inputs. To assess generalisation beyond the training cohorts, we performed external clinical validation on 30 routine brain MRI examinations from a Nigerian cohort, representing an under-represented population in medical imaging research. These examinations formed the largest component of a blinded reader study involving 44 real cases and seven expert neuroradiologists. In the Nigerian cohort, MS-HVED was preferred over the supervised baseline for overall image quality in 187 of 210 paired assessments. Across all clinical cohorts, MS-HVED achieved higher overall-quality scores with all available inputs (5.93 vs. 4.49, p<.001), with the preference persisting when axial or coronal inputs were omitted (p<.001). Code at github.com/cai4cai/ms-hved
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian PrototypesarXiv · 2026
- Beyond Outlier Rejection: Transient-Aware Reconstruction of Multi-Stack MRIarXiv · 2026
- Decoupling Multi-Contrast Super-Resolution: Self-Supervised Implicit Re-Representation for Unpaired Cross-Modal Synthesis.IEEE transactions on medical imaging · 2026
- Enhancing Diagnostic Accuracy of Brain MRI Using Super-Resolution AttentionGANIndian Journal of Science and Technology · 2026
- Brain MRI Super-Resolution with 2.5D Inter-Slice Context and Contourlet-Domain Conditioning.Medical engineering & physics · 2026
- PGDM-MRSRGAN: Physics-Guided Degradation Model with an SRGAN Framework for Magnetic Resonance Image Super-Resolution: Applications in Low-Field MRI.ArXiv · 2026