Lesion-Aware Explainable AI for Diabetic Retinopathy Grading from Fundus Images
Truong Thinh Nguyen, Hai Phong Nguyen, Truong Thanh Hung Nguyen, Giang Son Tran, Hung Cao
Key points
From the paper's conclusion- We propose the Consensus-Calibrated Explanation Map (CCEM), which fuses Grad-CAM++, Ada-SISE, and SmoothGrad Integrated Gradients (SG-IG) using image-specific weights derived from annotation-free reliability cues: deletion sensitivity, inter-method agreement, compactness, retinal containment, and peak structure.
Abstract
Post-hoc explanations of deep-learning models for diabetic retinopathy (DR) grading are difficult to trust because different attribution methods highlight different retinal regions for the same image, and a visually plausible heatmap does not show that the highlighted pixels drive the prediction. We propose the Consensus-Calibrated Explanation Map (CCEM), which fuses Grad-CAM++, Ada-SISE, and SmoothGrad Integrated Gradients (SG-IG) using image-specific weights derived from annotation-free reliability cues: deletion sensitivity, inter-method agreement, compactness, retinal containment, and peak structure. CCEM explains a frozen ordinal grader, an EfficientNet-B7 with CBAM and a scalar regression head, pre-trained on EyePACS 2015 in Stage 1 and fine-tuned on APTOS 2019 in Stage 2 with quadratic weighted kappa (QWK)-optimized thresholds; it reaches a QWK of 0.920 on the hidden Kaggle test set and 0.559 on the external MAPLES-DR cohort. Explanations are evaluated on MAPLES-DR, 198 MESSIDOR images with expert pixel-level lesion annotations that are never used for training, threshold fitting, or fusion. On the 193 images with annotated lesions, CCEM obtains the highest Soft Pointing Game score (69.61%; 95% CI 63.7-75.3), defined as the ratio of the strongest lesion-supported saliency to the global map maximum rather than a lesion detection rate, together with the lowest deletion AUC (0.570) and the best deletion-insertion balance (0.115); each gain is significant against the strongest single explainer on paired tests. Annotation-free, per-image reliability weighting therefore turns three disagreeing explainers into one map whose peak evidence is more lesion-supported and more faithful to the model than that of any single explainer.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- RobustDRNet: A clinically-aligned hybrid ensemble model with multi-method explainability for lesion-aware diabetic retinopathy gradingExpert Systems with Applications · 2026
- Explainable AI for diabetic retinopathy detection using vision transformersScientific Reports · 2026
- Calibrated Confidence and Confidence-Stratified Triage for Diabetic Retinopathy Severity Grading: A Class-Imbalance-Aware Deep Learning Study on the DDR Dataset.Bioengineering (Basel, Switzerland) · 2026
- CalibCause: A Quality-Gated, Interpretable and Calibrated Deep Learning Framework for Diabetic Retinopathy GradingarXiv · 2026
- Interpretable Diabetic Retinopathy Classification Using Hybrid ConvNeXt–MLP-Mixer and ConvNeXt–PoolFormer ArchitecturesJournal of Information Systems and Informatics · 2026
- A Study on the Interpretability of Diabetic Retinopathy Diagnostic ModelsBioengineering · 2025