A Multiobjective Optimization Framework for Sensor Array Design in Magnetocardiography
Kesavaraja C, Sammita Kashyap, Korak Biswas, Pranab Dutta, Kushal Patel
Key points
From the paper's conclusion- These results show that optimized placement helps alleviate the complexity of data redundancy and enhances the performance of MCG as a routine cost-effective clinical measurement.
Abstract
Magnetocardiography (MCG) noninvasively measures cardiac magnetic fields. Conventional cryogenic systems use fixed multichannel arrays, whereas room-temperature sensors enable flexible placement to reduce array size and measurement redundancy. The present study aims at developing a scheme to identify the optimal sensor placements by utilizing three methodological sensor optimization frameworks such as physics driven, experimental data driven and a hybrid combination of both. The physics-driven method optimizes continuous planar coordinates using D-optimality, spatial correlation, and leastsquares error. The data-driven method uses measured spatiotemporal fields and pole-geometry metrics, while the hybrid method integrates both approaches. The evaluation is performed using training objective, Pearson correlation, normalized root-meansquare error (NRMSE) and pole separation(mm), orientation({\deg}) and trajectory(mm) errors, where physics-driven optimization identified 16 sensors with a correlation of 0.9914 and an NRMSE of 0.0139, with pole separation, orientation, and trajectory errors of 3.71 mm, 1.38{\deg}, and 3.55 mm, respectively. Data-driven optimization shows diminishing improvements beyond 17 sensors, achieving correlation 0.9840, NRMSE 0.0035, and pole errors of approximately 4.30 mm, 1.70{\deg}, and 6.80 mm. The hybrid method achieves correlation 0.9945 and NRMSE 0.0201 with 14 sensors, reducing sensor count by 12.5% relative to the physics-driven configuration. Its pole errors of 6.50 mm, 2.31{\deg}, and 7.50 mm satisfy the study-defined thresholds, balancing array compactness with magnetic-field morphology preservation. These results show that optimized placement helps alleviate the complexity of data redundancy and enhances the performance of MCG as a routine cost-effective clinical measurement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enhancing Current-Source Imaging in Magnetocardiography: The Impact of Sensor Array Configuration.Annals of biomedical engineering · 2026
- High-precision cardiac magnetic field modeling and multi-source spatial reconstruction based on OPM-MCG: Experimental validationMeasurement Science and Technology · 2026
- Frequency-domain Based Optimization of Voxel Networks for Non-invasive Magneto-anatomical MappingCurrent Directions in Biomedical Engineering · 2026
- Physics-informed 3D source localization from multichannel seismocardiographyFrontiers in Signal Processing · 2026
- Maxwell-Consistent 3-D Magnetic Field Camera using Scalar-Potential-Based ReconstructionarXiv · 2026
- Optimal experimental design with k-space data: application to inverse hemodynamicsInverse Problems · 2026