Cracks in Embeddings: Robustness and Stability of JEPA-Based Chest X-Ray Representations
Zahid Mansur, Kalpana Yadav, Deepak Mishra
Key points
From the paper's conclusion- We test four JEPA-based chest X-ray encoders, trained on 78,468 NIH ChestX-ray14 images, under six tests: two black-box adversarial attacks (SPSA, Boundary Attack), three image corruptions (Gaussian noise, brightness shift, contrast shift), and a label-scarcity test, measuring embedding change and classification AUROC.
Abstract
Self-supervised Joint Embedding Predictive Architecture (JEPA) models are increasingly used for medical imaging, however there is a limited understanding about robustness of these models toward real-world image changes. We test four JEPA-based chest X-ray encoders, trained on 78,468 NIH ChestX-ray14 images, under six tests: two black-box adversarial attacks (SPSA, Boundary Attack), three image corruptions (Gaussian noise, brightness shift, contrast shift), and a label-scarcity test, measuring embedding change and classification AUROC. These perturbations cause severe, model-dependent damage: encoder-level Cosine Similarity drops as low as 0.33, and AUROC falls by as much as 0.12 in the worst case (I-JEPA under the Boundary Test). We test two ways of training the small predictor on top of each frozen encoder to address this. Adversarial fine-tuning, trained on clean and perturbed images together, raises embedding consistency above 0.97 in nearly every case and improves AUROC, relative to the same perturbed baseline, for most models, with the largest gain of $+0.10$ on I-JEPA. A Vector-Quantized codebook method, trained only on clean images and evaluated on perturbed test images for the first time, instead degrades under distortion for all four models, most noticeably for I-JEPA ($-0.15$ AUROC on average), showing that its discrete bottleneck alone does not provide the robustness that comes from training on perturbed data directly.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MADJEPA: Enhanced Multi-Stage Joint-Embedding Predictive Architecture for Medical Anomaly DetectionarXiv · 2026
- DuoJEPA: Cross-Modal Translation Between Unaligned Self-Supervised Embedding SpacesarXiv · 2026
- Evaluating the robustness of explainable AI in medical image recognition under natural and adversarial data corruptionMachine Learning · 2025
- DINOv3-SAM: Fusing Semantic and Anatomical Foundation Models for Robust Medical Image Classification.Journal of imaging informatics in medicine · 2026
- APED-CXR: Adaptive Privileged Evidence Distillation for Chest X-Ray Grounding with Image-Only InferencearXiv · 2026
- Quasi-Binarized Autoencoders: An Architecture-Independent Information Bottleneck for Medical Image Anomaly DetectionarXiv · 2026