Data-driven Correction Reduced-Order Stochastic Collocation Method for the Time-Dependent Navier-Stokes Equations
Md. Abdul Aziz, Muhammad Mohebujjaman, Xuping Xie
Key points
From the paper's conclusion- We develop two hybrid data-driven Uncertainty Quantification (UQ) Reduced-Order Models (ROMs) for the non-stationary incompressible Navier--Stokes Equations (NSEs) with random viscosity.
Abstract
We develop two hybrid data-driven Uncertainty Quantification (UQ) Reduced-Order Models (ROMs) for the non-stationary incompressible Navier--Stokes Equations (NSEs) with random viscosity. The proposed framework combines Proper Orthogonal Decomposition (POD) ROMs, spatial filtering, data-driven closure modeling, and the Stochastic Collocation Method (SCM). A key feature is the approximation of the realization-dependent closure term by the closure associated with the expected viscosity. Consequently, a single data-driven closure model constructed from the full-order solution corresponding to the expected viscosity can be reused across all realizations, thereby avoiding the expensive construction of realization-specific closure models. This leads to the Data-Driven Correction UQ ROM (DDC-UQ-ROM) and its physically constrained variant, the Constrained DDC-UQ-ROM (CDDC-UQ-ROM), in which physical constraints are imposed on the data-driven correction model. The proposed methods are evaluated for a two-dimensional (2D) flow past a circular cylinder problem with a 5D random viscosity field, considering mean Reynolds numbers $Re=100$ and $Re=500$, different correlation lengths, and both in-sample and out-of-sample parameter settings. Numerical results show that the DDC-UQ-ROM generally improves upon the standard Galerkin ROM (G-ROM), while the CDDC-UQ-ROM exhibits the most accurate and robust approximation of the benchmark energy evolution across the cases considered. The robustness and accuracy of the CDDC-UQ-ROM are further assessed through statistical error analyses of the first- and second-order energy moments, reduced-training-data experiments, and an indicative comparison of wall-clock computational costs with the full-order UQ calculations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intrusive versus non-intrusive reduced-order modeling of generalized Newtonian fluid flowsarXiv · 2026
- POD-CNF: reduced order modeling of parametrized stochastic PDEs via normalizing flows and proper orthogonal decompositionarXiv · 2026
- A Compact Residual-Screened Local Reduced-Order Model for Diffuse-Domain Shape OptimizationarXiv · 2026
- Data-driven stochastic reduced-order modelling of parametrized dynamical systemsProceedings of the Royal Society A Mathematical Physical and Engineering Sciences · 2026
- Parametric spatio-temporal reduced-order modelling via Spectral Proper Orthogonal Decomposition and Gaussian Process RegressionarXiv · 2026
- An Efficient Error-Controlled POD Reduced-Order Collocation Spectral Method for Unsteady Incompressible Navier–Stokes EquationsMathematics · 2026