Coarse-to-Fine 3D MRI Reconstruction via Resolution-Agnostic Neural Operators
Jiayun Wang, Ram Daftari, Weijie Gan, Valentin Duruisseaux, Ruibo Wang, Armeet Singh Jatyani, Boris Bonev, Anima Anandkumar
Key points
From the paper's conclusion- These results show that resolution-agnostic operators make coarse-to-fine 3D MRI reconstruction - cheap low-resolution training with high-resolution deployment - practical across anatomies.
Abstract
Deep-learning-based 3D MRI reconstruction is limited in practice by the GPU memory and compute cost of full-volume training; 3D acquisitions are thus most often reconstructed by 2D models applied slice-by-slice and then stacked, which ignores through-plane (stacking-axis) structure. We reconstruct in full 3D and ask whether a model can be trained at low resolution (fast and memory-feasible) yet deployed at higher resolution. This coarse-to-fine strategy needs reliable cross-resolution performance, but standard networks are resolution-specific and degrade substantially when evaluated outside the training setting. We therefore use resolution-agnostic neural operators (NOs) and propose KIR-NO (k-space-to-Image Reconstruction Neural Operator), a discretization-agnostic framework for accelerated 3D MRI reconstruction. KIR-NO is trained with full backpropagation on low-resolution volumes and applied zero-shot to higher-resolution volumes at inference. Its core building block is a 3D neural operator based on discrete-continuous convolutions: convolutional filters are parameterized in a continuous basis and sampled at arbitrary voxel resolutions while preserving the local inductive bias of convolution. KIR-NO integrates these learned operators with physics-based consistency: a k-space neural-operator head first refines the undersampled Fourier measurements, and image-space neural-operator cascades then refine the reconstruction through interleaved data-consistency updates. Across 3D knee and brain MRI benchmarks, KIR-NO improves over classical and CNN baselines: it improves over a state-of-the-art 3D CNN by 2.2 dB PSNR at half resolution under 4x acceleration on SKM-TEA, with gains persisting at 8x and 16x. These results show that resolution-agnostic operators make coarse-to-fine 3D MRI reconstruction - cheap low-resolution training with high-resolution deployment - practical across anatomies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Efficient 3D Medical Reconstruction from Sparse Views via 2D Diffusion Models with Curvature Priors.IEEE transactions on image processing : a publication of the IEEE Signal Processing Society · 2026
- A K-space guided invertible diffusion model for accelerating MRI reconstruction.Medical physics · 2026
- Unsupervised high-resolution 3D MRI motion correction via physics-informed implicit neural representations.Medical image analysis · 2026
- Learning Fourier-Constrained Diffusion Bridges for MRI ReconstructionIEEE Transactions on Medical Imaging · 2026
- Scalable Unrolled Chains for MRI ReconstructionarXiv · 2026
- Physics-based simulation unlocks scaling laws for generalizable MRI reconstructionarXiv · 2026