Key points
From the paper's conclusion- We present CT-RespGeomLib, a deterministic framework that converts CT airway masks into two complementary representations: an editable assembly of semantically labelled pipe and junction blocks connected through canonical shared ports, and a fused lumen surface reconstructed from tapered implicit primitives with validated port-to-boundary loop correspondence.
Abstract
Patient-specific airway modelling requires geometrically consistent lumen surfaces with identifiable boundaries and support for controlled anatomical modifications. We present CT-RespGeomLib, a deterministic framework that converts CT airway masks into two complementary representations: an editable assembly of semantically labelled pipe and junction blocks connected through canonical shared ports, and a fused lumen surface reconstructed from tapered implicit primitives with validated port-to-boundary loop correspondence. The parametric representation further enables localised modelling of airway stenosis and dilation without re-segmentation. Evaluated on 42 reference airway masks from ATM22 (15 cases) and AeroPath (27 cases), the framework produced 37 topologically accepted reconstructions, with a median port-to-loop distance of 0.123 mm across 2174 matched ports. Reconstructed and reference equivalent radii showed strong agreement ($R^2 = 0.976$), with a mean bias of -0.414 mm arising primarily from the circular, inscribed-radius representation. Controlled pathology modelling generated 40 variants across five patient-specific geometries, including 25-75% stenosis and 50% dilation at tracheal and main-bronchus locations. Prescribed radius changes were reproduced with a mean absolute ratio error of 0.0056, while the median 95th-percentile deviation outside the modified region was 0.111 mm. Downstream applicability was demonstrated through volume meshing and an OpenFOAM simulation with individually prescribed model-based resistance conditions at 62 outlets. Although additional surface preparation may be required for numerical meshing, CT-RespGeomLib provides a reproducible framework for CT-derived airway reconstruction, quantitative boundary validation and controlled geometric pathology modelling.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Airway image analysis systems: a review of datasets, evaluation methodologies, and deep learning approaches.Frontiers in digital health · 2026
- CFD Modeling of Airflow and Aerosol Transport in the Human Respiratory System: A Comprehensive ReviewPharmaceutical Research · 2026
- BronchoTop: Bronchoscopy Navigation via RGB-Only Topological LocalizationarXiv · 2026
- CTrex: A Research-Oriented Framework for Kernel- and Projection-Level Algorithm Development in CT ReconstructionarXiv · 2026
- Nasal-HNet: A multimodal hierarchical network for joint anatomical and functional assessment of nasal obstruction from CBCT and clinical dataAIP Advances · 2026
- CT-Based Pulmonary Segment Delineation: An Imaging Informatics Review of Methods, Benchmarks, Robustness, and Clinical Deployment.Journal of imaging informatics in medicine · 2026