arXivPreprintOpen accessphysics.flu-dyn

Experimental Investigation of Heat Transfer in Axisymmetric Open Cavities at Hypersonic Speeds

T. V. Krishna, J. Cohen, S. K. Karthick, Soumya R. Nanda

Key points

From the paper's conclusion
  • The results indicate that increasing the cavity length-to-depth ratio leads to a reduction in the downstream Stanton number $(St_d)$.

Abstract

An experimental investigation was conducted to characterize the heat-transfer behavior of an axisymmetric cavity mounted on a cone with a semi-apex angle of $(48^ \circ)$ under Mach 6 freestream conditions in a Ludwieg tunnel. The effects of cavity geometry, represented by the length-to-depth ratio $(L/D = 0.5, 1.0, 2.0, 4.0,$ and $6.0)$, rear-wall height-to-depth ratio $(h/D = -0.25, 0,$ and $0.5)$, and Reynolds number ($Re_D = 23000 - 74000$) were systematically investigated. Flow-field characteristics and surface heat-transfer behavior were examined using schlieren and planar laser Rayleigh scattering visualization techniques, together with surface pressure and heat-transfer measurements. The results indicate that increasing the cavity length-to-depth ratio leads to a reduction in the downstream Stanton number $(St_d)$. For the longest cavity $L/D = 6$, however, the downstream Stanton number was found to exceed the upstream value $(St_u)$ indicating enhanced heat transfer in the region downstream of the cavity.

Read the paper