RBA: A Read-out Basis Adapter for Parameter-Efficient Interactive OCTA Vessel Segmentation with SEEM
Jaafar M. Al-Ghabban, Mohammad Reza Mohammadi
Key points
From the paper's conclusion- This study introduces the Read-out Basis Adapter (RBA), whose read-out branch generates 32 image-specific basis maps at half resolution.
Abstract
Retinal disease monitoring with optical coherence tomography angiography (OCTA) relies on segmentation of vessels and the foveal avascular zone (FAZ). Promptable models such as SEEM (Segment Everything Everywhere All at Once) allow click-based refinement, but without adaptation SEEM segments thin vessels poorly and needs many clicks. Fully fine-tuning its 342 million parameters on a few hundred images is costly and risks overfitting, and parameter-efficient methods such as low-rank adaptation (LoRA) usually adapt only the encoder. Yet SEEM reads every candidate mask from one feature map at quarter resolution, too coarse for vessels one to three pixels wide. This study introduces the Read-out Basis Adapter (RBA), whose read-out branch generates 32 image-specific basis maps at half resolution. Each candidate accesses them through its own vector and a zero-initialised projection, so the model starts exactly as SEEM. The encoder branch, a standard rank-1 LoRA, supplies the information needed to tell arteries from veins. RBA adds 0.47 million trainable parameters. Under simulated error-driven clicks, with the ground truth used only to place them, RBA outperforms LoRA, Conv-LoRA andAdaptFormer on OCTA-500 3mmlarge vessels. Averaged over three seeds, it reaches an intersection over union (IoU) of 85.16% and a Dice score of 91.93%, 2.90 and 1.72 percentage points above Conv-LoRA. On the 6 mm subset, one run gives margins of 4.35 and 2.76 points. The gain extends to arteries, veins and ROSE-O but not to the FAZ. In SEEM, adaptation capacity pays more at the mask read-out than in the encoder.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- De-Seg: Advancing OCTA segmentation with multi-scale feature fusion and edge refinement.Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2026
- CVP-BAA: Efficiently Adapting Segment Anything Model for Medical Image SegmentationarXiv · 2026
- ReTailor: A Residual Feature Tailoring Framework for Real-Time Cross-Sensor Pansharpening AdaptationarXiv · 2026
- RetiDual-Select: Reliability-Aware Specialist-Generalist Routing for Retinal OCT under Image-Quality ShiftarXiv · 2026
- Continual Low-Rank Adaptation Via Cumulative Unified Optimization.IEEE transactions on pattern analysis and machine intelligence · 2026
- A Few Cases Are All You Need: An Empirical Study of Annotation-Efficient LoRA Fine-Tuning of MedSAM3arXiv · 2026