Differentiable topology optimization for high-fidelity acoustic holography beyond the thin-element approximation
Pradosh Pritam Dash, Costas D. Arvanitis
Key points
From the paper's conclusion- Here we show that the heterogeneous angular spectrum approach (HASA), which admits in-plane varying speed-of-sound maps and supports rapid differentiable optimization with the Adam optimizer, can generate three-dimensional lens topologies directly.
Abstract
Acoustic holography in the megahertz range can impact applications from manufacturing and non-destructive testing to transcranial ultrasound. Designing lens topologies for complex holograms in the sub-megahertz to low-megahertz regime most relevant to transcranial therapy is difficult because wave propagation through an acoustically thick lens cannot be ignored. Here we show that the heterogeneous angular spectrum approach (HASA), which admits in-plane varying speed-of-sound maps and supports rapid differentiable optimization with the Adam optimizer, can generate three-dimensional lens topologies directly. With it we quantify the failure of the thin-element approximation (TEA) at these frequencies, where lenses enter an acoustically thick regime (thickness L much greater than the wavelength) governed by refractive walk-off, and we introduce a dimensionless refractive walk-off number Nw that defines a frequency-dependent operating regime. Topology optimization outperformed TEA-based design in all 45 configurations tested, with the largest structural gains at or below 1 MHz; for high-numerical-aperture designs the fidelity at 1 MHz matched that at 2 MHz, while structural similarity was highest at 0.5 MHz. The sub-megahertz to low-megahertz window is therefore a favorable operating regime for high-fidelity transcranial holography rather than one to be avoided. Free-field hydrophone measurements of 3D-printed lenses reproduced the designed patterns, and because the framework also accounts for aberration in heterogeneous media, patient-specific lenses corrected skull-induced aberration in simulation and ex vivo experiment, generalized across skull segments, and shaped volumetric beams through the human skull. Together these results provide a framework for designing simple, economical, and high-performance ultrasound systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Subwavelength Topology Optimization With Feature‐MappingInternational Journal for Numerical Methods in Engineering · 2026
- Generalized Apodization Design with Learned Complex-Valued Weights for High-Frame-Rate Ultrasound Beamforming.IEEE transactions on ultrasonics · 2026
- Reconfigurable dynamic acoustic holography with acoustically transparent and programmable metamaterialNature Communications · 2025
- Super‐Resolution and High‐Data‐Density Acoustic Meta‐Hologram via Amplitude and Phase CouplingAdvanced Science · 2026
- Wave-optical adaptation of feed-forward 4D Gaussian splatting for real-time dynamic holographic renderingEngineering Research Express · 2026
- Subwavelength registration of skull-compensating acoustic holograms via nonlinear parametric array feedbackarXiv · 2026